SS 16.16 Installation and Operation Manual
INSTALLATION
Mounting:
The SS 16.16 is designed to be rack mounted in a standard 19” rack, (2 – RU). It
should be mounted in an area that is accessible from the rear and preferably away
from sources of heat. We recommend before permanently installing the SS 16.16,
you bench test and become familiar with the operation of the unit.
Power Supply Connection:
Install the 5-pin “DIN” connector into the DIN receptacle on the SS 16.16. Mount
the power supply in a convenient location. When ready, plug the cord into the
appropriate AC receptacle.
NOTE: Only use IPS model HUP45-32
Baud Rate DIP Switches
SW1 – 4
Baud Rate
OFF
9600
ON
38400
Open Collector Follow Mode DIP Switches
SW1 – 6
Mode
OFF
OC
Follow
ON
OC Pulse
Power up/Last source DIP Switch
SW1 – 7
Function
OFF
User
Programmable
ON
Last Source(s)
selected
Open Collector control DIP Switch
SW1 – 8
Function
OFF
Enable SW1-6
ON
Software control
of Open
Collectors