e-mail:
voice:
360.854.9559
fax:
866.783.1742
15
SS 16.16 Installation and Operation Manual
INSTALLATION
Serial Control:
The unit is controlled in either Menu or Burst mode. It can run at the following data
rates: 9600 (default) and 38,400 Serial communications is multi-drop RS-232.
Commands may be entered either via a menu (menu mode) or a short form code
(burst mode). All commands and responses use normal ASCII characters, facilitat-
ing scripting. A burst mode command starts with an asterisk (“*”) followed by the
device (ID) address as a single decimal digit. A burst mode command must be
entered within 5 seconds or it will time out. The command to enter menu mode
starts with an asterisk (“*”) followed by the device (ID) address as a single decimal
digit and then MM. The menu mode displays certain parameters, and allows the set-
ting of these parameters. In both cases, device (ID) address (0-7) is specified with
the on-board dipswitches.
Menu Mode:
Type *0MM, follow the prompts on the pop-up menu.
The command to enter menu mode starts with an asterisk (“*”) followed by the
device (ID) address as a single decimal digit, then the MM command.
NOTE: Commands you type will NOT be seen, unless you turn “Echo On” in
HyperTerminal.
The menu mode displays advanced configuration parameters. Unit ID, Baud rate
and other configurations are set via the rear panel dipswitches (SW1).
Broadcast Tools® SS 16.16, v1.X - Setup Menu
1 - Set PIP Minimum (0 - 2.55 sec)
- Now: .05
A - Save Current Audio State for Power Up
C - Show Current Configuration
N – Set name for Input
F - Set Factory Defaults
Enter Selection, or Q to quit: