IMPORTANT INFORMATION
In AC output mode, the three phases are independently programmable. If the -1P
option is added, the output AC current range will be expanded. For example, in
ESA
30-300-46
, the standard output AC current is 46A/phase. If the -1P option is
added (Add single phase output function), after changing the corresponding
wiring, the maximum single-phase AC current can be output 138A.
(when related to wiring issues, please combine 2.2.2 and 2.2.3)
5.6.2
AC+DC
The ESA series support AC+DC output mode.
Test steps:
Click "Sequence" to enter the panel, select AC+DC output mode (AC+DC) on the right side
(Figure 5-13
③
), the user can choose different operating modes (CV/CC) according to the test
requirements, and set the AC voltage/current and DC offset voltage/current (Figure 5-14).
After setting the parameters, click "Apply"→"Power On"→"Output On" in turn, and the power
supply is on.