25
GLASS “SOOT’S” UP AT A VERY FAST RATE
FLAME IS LAZY, DARK, AND HAS BLACK TIPS
AFTER STOVE HAS BEEN ON FOR A WHILE, THE BURNPOT OVERFILLS
Possible Causes:
Possible Remedies:
Stove or vent pipe is dirty, which restricts airflow
through the burnpot.
Follow all cleaning procedure in the maintenance section of the
owner’s manual.
Vent pipe installed improperly.
Check to make sure the vent pipe has been installed according to the
criteria in the owner’s manual.
Air damper is set too far in (closed) for a higher
setting.
Pull the damper knob farther out away from the side of the stove and
try to burn the unit again.
Burnpot holes are blocked.
Remove the burnpot and thoroughly clean it.
Air damper is broken.
Visually inspect the damper assembly. Make sure the damper plate
is attached to the damper rod. When the damper rod is moved the
plate should move with it.
Blockage in air intake pipe.
Visually inspect the air intake pipe that leads into the burnpot for
foreign material.
Circuit board malfunction.
Time the fuel feed light at each setting (after the stove has completed
the startup cycle). Make sure the times match the auger timing chart.
If the auger motor runs constantly, the board is bad.
Combustion blower is not spinning fast enough.
Test the RPM on the blower after the blades have been cleaned. The
RPM should be approximately 3000 RPM.
Bad Pellets (Applies to GLASS “SOOT’S” UP AT A
VERY FAST RATE Only)
The brand of pellets or the batch of pellets that are being used may
be of poor quality. If possible, try a different brand of pellets. You
might also want to try a brand that is made from a different type
of wood (softwood vs. hardwood). Different woods have different
characteristics when being burned.
The trim setting on the low feed rate is to low
(Applies to GLASS “SOOT’S” UP AT A VERY FAST
RATE Only)
Use the “Reset Trim” button to increase the low feed rate setting. If the
1 & 4 are on, the stove is currently on the lowest setting. If only the
1 light is on, the stove is in the default (medium) setting. If the 1 & 5
lights are on, the stove is in the high trim setting for the low feed rate.
If the stove is being burned on one of the two lower settings, advance
to the next trim setting and try burning the stove.