4
© 2020 Breckwell Hearth
INSTALLATION
SAFETY NOTICE
• IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE
FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE,
FOLLOW THE INSTALLATION INSTRUCTIONS.
• CONTACT YOUR LOCAL BUILDING OFFICIALS TO
OBTAIN A PERMIT AND INFORMATION ON ANY
ADDITIONAL INSTALLATION RESTRICTIONS OR
INSPECTION REQUIREMENTS IN YOUR AREA.
• DO NOT PLACE CLOTHING OR OTHER FLAMMABLE
ITEMS ON OR NEAR THIS STOVE.
• NEVER USE GASOLINE, GASOLINE-TYPE LANTERN
FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR
SIMILAR LIQUIDS TO START OR ’FRESHEN UP’ A FIRE
IN THIS STOVE. KEEP ALL SUCH LIQUIDS WELL AWAY
FROM THE STOVE WHILE IT IS IN USE.
• INSTALL VENT AT CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER.
• DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST
VENTING SYSTEM OF THIS UNIT.
• YOUR STOVE REQUIRES PERIODIC MAINTENANCE
AND CLEANING (SEE “MAINTENANCE”). FAILURE TO
MAINTAIN YOUR STOVE MAY LEAD TO IMPROPER
AND/OR UNSAFE OPERATION.
• A POWER SURGE PROTECTOR IS REQUIRED. THIS
UNIT MUST BE PLUGGED INTO A 110 - 120V, 60 HZ
GROUNDED ELECTRICAL OUTLET. DO NOT USE AN
ADAPTER PLUG OR SEVER THE GROUNDING PLUG.
DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH,
IN FRONT OF, OR OVER THE HEATER. DO NOT ROUTE
THE CORD IN FOOT TRAFFIC AREAS OR PINCH THE
CORD UNDER FURNITURE.
CAUTION:
BURNING FUEL CREATES CARBON MONOXIDE AND CAN
BE HAZARDOUS TO YOUR HEALTH IF NOT PROPERLY
VENTED.
ATTENTION:
• A WORKING SMOKE DETECTOR MUST BE INSTALLED
IN THE SAME ROOM AS THIS PRODUCT.
• INSTALL A SMOKE DETECTOR ON EACH FLOOR OF
YOUR HOME; INCASE OF ACCIDENTAL FIRE FROM
ANY CAUSE IT CAN PROVIDE TIME FOR ESCAPE.
• THE SMOKE DETECTOR MUST BE INSTALLED AT LEAST
15 FEET (4,57 M) FROM THE APPLIANCE IN ORDER
TO PREVENT UNDUE TRIGGERING OF THE DETECTOR
WHEN RELOADING.
CAUTION:
• DO NOT UNPLUG THE STOVE IF YOU SUSPECT A
MALFUNCTION. TURN THE ON/OFF SWITCH TO
”OFF’ AND CONTACT YOUR DEALER. TURNING THE
STOVE “OFF” DOES NOT DISCONNECT ALL POWER
FROM THE STOVE.
• THE HEATER WILL NOT OPERATE DURING A POWER
OUTAGE. IF A POWER OUTAGE DOES OCCUR, CHECK
THE HEATER FOR SMOKE SPILLAGE AND OPEN A
WINDOW IF ANY SMOKE SPILLS INTO THE ROOM.
• DO NOT OPERATE YOUR STOVE IF YOU SMELL SMOKE
COMING FROM IT. TURN IT OFF, MONITOR IT, AND
CALL YOUR DEALER.
• NEVER BLOCK FREE AIRFLOW THROUGH THE OPEN
VENTS OF THE UNIT.
WARNING:
• IF THE STOVE IS INSTALLED IN A ROOM WITHOUT
AIR CONDITIONING, OR IN AN AREA WHERE DIRECT
SUNLIGHT CAN SHINE ON THE UNIT, IT IS POSSIBLE
THIS CAN CAUSE THE TEMPERATURE OF THE STOVE TO
RISE TO OPERATIONAL LEVELS; ONE OF THE SENSORS
COULD THEN MAKE THE STOVE START ON ITS OWN. IT
IS RECOMMENDED THAT THE STOVE BE UNPLUGGED
WHEN NOT IN USE FOR EXTENDED AMOUNTS OF
TIME (I.E. DURING THE SUMMER MONTHS).
• THE EXHAUST SYSTEM MUST BE COMPLETELY AIRTIGHT
AND PROPERLY INSTALLED. THE PELLET VENT JOINTS
MUST BE SEALED WITH RTV 500°F (260°C) SILICONE
SEALANT, AND WITH UL-181-AP FOIL TAPE.
Breckwell Hearth highly recommends your stove be installed
by a qualified NFI (US) or WETT (Canada) technician. To
find the nearest qualified installer, go to:
https://nficertified.org
,
https://www.wettinc.ca/
PREPARATION
Factory packaging must be removed, and some minor
assembly work is required prior to installation. Access to
FOR CUSTOMER ASSISTANCE CALL YOUR BRECKWELL DEALER OR EMAIL: WWW.BRECKWELL.COM
Summary of Contents for SP24i
Page 31: ...2020 Breckwell Hearth 31 NOTES...