OPERATION
WARNING:
• DO NOT OPERATE THE STOVE IF THE FLAME BECOMES
DARK AND SOOTY OR IF THE BURNPOT OVERFILLS
WITH PELLETS. TURN THE STOVE OFF, PERIODICALLY
INSPECT IT, AND CALL YOUR DEALER.
• IF THE STOVE IS INSTALLED IN A ROOM WITHOUT
AIR CONDITIONING, OR IN AN AREA WHERE DIRECT
SUNLIGHT CAN SHINE ON THE UNIT, IT IS POSSIBLE
THIS CAN CAUSE THE TEMPERATURE OF THE STOVE TO
RISE TO OPERATIONAL LEVELS; ONE OF THE SENSORS
COULD THEN MAKE THE STOVE START ON ITS OWN. IT
IS RECOMMENDED THAT THE STOVE BE UNPLUGGED
WHEN NOT IN USE FOR EXTENDED AMOUNTS OF
TIME (I.E. DURING THE SUMMER MONTHS).
PANEL CONTROLS
5
The blowers and automatic fuel supply are controlled from
a panel on the left-hand side of the stove. The control panel
functions are as follows.
a. ON/OFF SWITCH
• When pushed the stove will automatically ignite. No
other firestarter is necessary. The igniter will stay on for
at least 10 and up to 15 minutes, depending on when
Proof of Fire is reached. The fire should start in about 5
to 7 minutes.
• The green light located above the On/Off button (in the
On/Off box) will flash during the ignition start-up period.
• The Heat Level Advance is inoperable during the ignition
start period. When the green light continuously stays on
the Heat Level Advance can be adjusted to achieve the
desired heat output.
NOTE: When not connected to a thermostat if the stove has
been shut off, and you want to re-start it while it is still warm,
the “on/off” button must be held down for 2 seconds.
b. FUEL FEED SWITCH
• When the “Fuel Feed” button is pushed and held down
the stove will feed pellets continuously into the burnpot.
• While the stove’s auger system is feeding pellets the green
light (in the “Fuel Feed” box) will be illuminated.
CAUTION:
DO NOT USE THIS CONTROL DURING NORMAL
OPERATION BECAUSE IT COULD SMOTHER THE FIRE AND
LEAD TO A DANGEROUS SITUATION.
c. HIGH FAN SWITCH
• The room air fan speed varies directly with the feed rate.
The “HIGH FAN” switch overrides this variable speed
function. It will set the room air blower speed to high at
any feed rate setting.
• When the “HIGH FAN” button is pushed the room air fan
will switch to its highest setting.
• When this button is pushed again the room air fan will
return to its original setting based on the Heat Level
Advance setting.
d. RESET TRIM
Different size and quality pellet fuel, and installation
altitude, may require adjustment of the “1” feed setting on
the Heat Level Advance bar graph. This is usually a one-time
adjustment based on the fuel you are using. The “RESET
TRIM” button, when adjusted, will allow for 3 different feed
rate settings for the #1 feed setting only. To adjust simply
push the “RESET TRIM” button while the stove is operating
at setting “1” and watch the bar graph.
• When the “1” & “3” lights are illuminated on the bar
graph the low feed rate is at its “lowest” setting. (Approx.
0.9 pounds per hour)
• When the “1” light is illuminated on the bar graph the
low feed rate is at its “normal” setting.
• When the “1” & “4” lights are illuminated on the bar
graph the low feed rate is at its “highest” setting. (Approx.
1.1 to 1.2 pounds per hour)