TESTED and LISTED to CAN/ULC

S627 AND UL 1482

Meets the Environmental Protection

Agency's

July 1990 Particulate Emission

Standards

INSTALLATION

& OPERATION

GUIDE

Design - D

Model

FUSION

PLEASE SAVE THESE INSTRUCTIONS

SAFETY NOTICE

If this stove is not properly installed,
a house fire may result.  For your
safety, follow the installation
instructions.  Contact local building
or fire officials about restrictions
and installation inspection
requirements in you area.

010604-16

FUSION_D1

5055.516

Summary of Contents for Fusion

Page 1: ...TION OPERATION GUIDE Design D Model FUSION PLEASE SAVE THESE INSTRUCTIONS SAFETY NOTICE Ifthisstoveisnotproperlyinstalled a house fire may result For your safety follow the installation instructions C...

Page 2: ...on 8 Clearances 8 Chimney and Connector 8 Double Wall Connector 8 Single Wall Connector 8 Procedure 8 Floor Protector 9 Combustion Air 9 Operation 10 Wood Selection 10 How to Test Your Wood 10 Lightin...

Page 3: ...nwoodandtoo slow a burning rate This heavy deposit is building up at least as quickly in the chimney WARNING ONLY USE MATERIALS SUPPLIED BY MANUFACTURER WHEN DOING MAINTE NANCE OR REPLACEMENTS 4 DOOR...

Page 4: ...ust be lived with Regular inspection and cleaning is the solution The use of dry seasoned wood and ample com bustion air will help to minimize the buildup Chimney Fires The result of excessive creosot...

Page 5: ...9 8 1 4 8 1 4 4 1 4 4 1 4 18 22 11 1 4 11 1 4 25 22 1 4 36 1 4 23 1 2 26 3 4 8 3 8 33 1 2 Minimum Clearance to Combustibles FIG 1 Double Wall Connector Residential Single Wall Connector Residential Al...

Page 6: ...instructions 7 Attach stove to flooring using two 1 4 x 2 or longer lag screws Warning Under no circumstances is this heater to be installed inamakeshiftor temporary manner Itmaybefiredonlyafter the...

Page 7: ...el DBSP 3 Energy Vent 7 Industrial Chimney Model Excel Ultra Black 4 Selkirk Metalbestos Model DS 8 Simpson Dura Vent Model DVL B As well as one of the following compatible chimney systems All parts 6...

Page 8: ...meetalllocalcodes Donotconnectthisunittoachimney flue serving another appliance Minimum system height is 15 feet 4 6 m measured from base of appliance Double Wall Connector Use a listed double wall co...

Page 9: ...ct Outside air may also be ducted from outside through the 4 diameter knockout hole in the rear of the pedestal enclosure Note Thisunitisnotdesignedtobeoperatedwiththefiring door open In addition to t...

Page 10: ...very important that the room be well ventilated Open all windows and doors Smoke and fumes caused by the curing process may cause discomfort to some individuals Lighting a Fire WARNING Never use chem...

Page 11: ...ler Re install baffle assembly in reverse order The two side pieces of insulation must be tight against the siderails Restarting After Extended or Overnight Burns 1 Open door and rake hot embers towar...

Page 12: ...firebox 8 Install the two screws through the flange of the blower into the rear shield 9 Plugthepowersupplycordinandcheckbloweroperation Power Cord Clearance Tab Temperature Switch Blower Operation Pr...

Page 13: ...dup See 1 2 3 above Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Won t Burn Overnight 1 Air control i...

Page 14: ...ost Manifold 4105 All parts may be ordered from your nearest Pacific Energy dealer Contact Pacific Energy for the location of the dealer nearest you 12a Firebrick 1 1 2 x 4 1 2 x 1 1 4 1 pc 248 12b Fi...

Page 15: ...ACK AS INDICATED MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS COMPONENTS REQUIRED FOR MOBILE HOME AND ALCOVE INSTALLATION OUTSIDE AIR KIT AND ONE OF THE FOLLOWING LISTED CONNECTORS SECURITY MODELS DP O...

Page 16: ...PACIFIC ENERGY FIREPLACE PRODUCTS LTD 2975 Allenby Rd Duncan BC V9L 4T8 Phone 250 748 1184 Web site http www pacificenergy net...

Reviews: