4.7 Magnet Rack - adjustment
Before placing the magnet rack in the printer, two adjustments must be checked.
The first is the distance between the support list and the pivot arms. This is the travelling distance for
the pivot arm. And it should be adjusted to about 0.8 mm using a feeler gauge. Adjust the nuts on both
ends of the magnet rack.
If the 0.8 mm feeler gauge goes in, and the 0.9 mm feeler gauge does not, consider the adjustment
OK.
Make sure that the nuts are tight when you are done!
0.8 mm feeler gauge
Adjust with these nuts
BRAILLO
l
NORWAY AS
B 300 S2
50
Summary of Contents for 300 S2
Page 1: ...User s Guide BRAILLO L NORWAY FOR BETTER BRAILLE AND MORE BRAILLO 300 S2 Rev June 2017 ...
Page 2: ... 2017 Braillo Norway AS ...
Page 4: ...BRAILLO l NORWAY AS B 300 S2 4 ...
Page 79: ...Frame complete BRAILLO l NORWAY AS B 300 S2 79 ...