background image

5

XC/310 receiver, or by means of PCS/300 by selec-
ting the corresponding receiver.

Programming melodies and number of rings

To enter programming mode, lift the receiver and
press the button underneath 

A

(fig. 6) 5 times,

within 5 s. 

A short audible signal sounds to confirm you have
entered programming mode (you automatically enter
the entry panel call melody programming procedure).
To repeat the procedure to enter programming
mode, hang up and wait at least 5 s.

Press the door lock release button to run through
the different modes in sequence.
A number of short audible signals sound to indica-
te that you have entered the corresponding mode:

no. 1 audible signal:

programming of melody asso-

ciated with the call from the entry panel.

no. 2 audible signals:

programming of melody asso-

ciated with doorbell.

no. 3 audible signals:

programming of number of

rings announcing a call.

SW2

P1

SW1

16

17

18

1 - Programming of melody associated with the call
from the entry panel

The first entry panel call melody is played repea-
tedly, alternated with a short audible signal.
To listen to the next melody, press the auxiliary but-
ton 2 (

) during the pause between the audible

signal and melody.
Repeat the operation until you hear the melody you
want.
To save the new setting without programming
anything else, hang up; otherwise, press the door
lock release button to call up the next programming
procedure.

2 - Programming of melody associated with doorbell

The first doorbell melody is played repeatedly, alter-
nated with two short audible signals.
To listen to the next melody, press the auxiliary but-
ton 2 (

) during the pause between the audible

signal and melody.
Repeat the operation until you hear the melody you
want.
To save the new setting without programming
anything else, hang up; otherwise, press the door
lock release button to call up the next programming
procedure.

3 - Programming of number of rings announcing a call

Three short audible signals sound. 
Decide how many rings you want and press the
auxiliary button 2 (

) the corresponding number of

times (in the range 1 to 6).

In system 300 installations, you can increase the
number of rings to a maximum of 51 by customizing
control unit XA/300LR.

3 s after the button was last pressed, you will hear
the call selected for the chosen number of rings.
If you want to save settings without programming
anything else, hang up; otherwise, press the door
lock release button to enter the entry panel call
melody programming procedure again.

NOTE. When you exit programming mode, the last
settings selected for each programming procedure
are saved.
For a setting to be taken as selected, you must have
heard it at least once.

Function of each terminal (fig. 10)
Terminal block M1

power supply local
from 12÷16 V AC or 14÷18 V DC

B

X1 line

+

doorbell input

Terminal block M2

connection for 
YAL loudspeake

Function of connectors
CN1 (position A) for YP3 accessory:

pushbuttons

are used to make intercom calls from 1 to 3 (or for
auxiliary functions from 3 to 5).

CN2 (position B) for YP3 accessory:

pushbuttons

are used to make intercom calls from 4 to 6 (or for
auxiliary functions from 6 to 8).

CN3 for YPL accessory

.

CN4 for YV or YVC monitor

.

Technical features

• Supply voltage: local 12 to 16 V AC or 14 to 18 V

DC, centralized 14 to 18 V DC.

• Power supply from bus: 15÷20 V DC.
• Current demand without monitor module: 100 mA

max. (<1 mA quiescent).

• Number of receivers activated at the same time

by X1 BUS: 1.

• Maximum number of receivers that can be con-

nected to control unit XA/300LR: 100 without YPL.

• Maximum number of receivers that can be con-

nected to an X1 entry panel: 64 without YPL (100
with XAS/301). 

• X1 connection line: non polarized twisted pair

Z=100 

.

• Working temperature range: 0 °C to +35 °C.  

WARNING. In installations with XA/300LR we
recommend you gather up the receiver’s ID (SN)
codes, applied on the outside of the housing, and
enter them in the tables that come with the
XA/300LR, MPP/300LR and IPC/300LR.

YV MONITOR MODULE

It is equipped with the following controls:

Brightness

Contrast

Technical features

• CCIR (EIA) standard.
• Picture screen: 4” (10 cm).
• Current demand: 350 mA max. 
• Bandwidth response at -3 dB: 5 MHz.
• Horizontal frequency: 15,625 Hz (15,750 Hz EIA).
• Vertical frequency: 50 Hz (60 Hz EIA).
•  Working temperature range: from 0 °C to +35 °C.

YVC MONITOR MODULE

It is equipped with the following controls:

Brightness

Saturation colour

Technical features

• PAL standard.
• Display: 3,5” LCD colour, active matrix.
• Current demand: 360 mA max.
•  Working temperature range: from  0 °C to +35 °C.

VIDEO ENTRY PANEL HEV/301

Single-button video entry panel for managing the
whole installation.
Teamed with button plates HEP/306-HEP/312D,
installations with up to 64 users can be set up.
For connections to user extensions the entry panel
uses BPT 

X1 TECHNOLOGY

bus connection, ena-

bling all signals involved in installation to be sent
along a telephone-type single twisted pair line.
An additional three video-entry or audio-only entry
panels can be added to the first in series without
the need for other equipment (selectors, distribu-
tors).
The entry panel comes ready to house the KHSO
luminous system busy warning kit and 1 KHPS (or 1
KHPD) call kit.
The entry panel comes complete with:
- CCD camera with ±11° manual angle adjustment
both horizontally and vertically (fig. 14), with fixed-
focus lens (see fig. 15 for dimensions of the target
area);
- phonic unit;
- infrared LED for lighting the target area;
- three potentiometers for the following functions
(fig. 14-16):

volume control at entry panel;
volume control at receiver;

P1

timed (in the range 1 to 15 s) solenoid door-lock

release.
The entry panel comes with system busy and door-
lock release buzzer.
The wires supplied make it simple to connect the
entry panel’s various component units.

Function of each terminal

14-18V DC
power supply  
solenoid lock output
door-lock release button

earth for solenoid lock
auxiliary command 1 output
auxiliary command 2 output
entry panel enabling output

B IN

bus input from 
other entry panels 

B OUT

bus output towards receivers or other entry
panels 

Connector functions
5-pin CN1 connector:

used for connection to entry

panel HEP/306 or HEP/312D.

3-pin CN3 connector:

used for connection to but-

tons KHPS or KHPD.

1-red:

to button n° 2.

2-orange:

to button n° 3.

3-yellow:

to button n° 4.

WARNING. In installations with a number of entry
panels, call buttons must be arranged in the same
order on each.

Connector CN4:

comes ready connected. 

1-black:

to button no. 1. 

2-brown:

to button no. 1. 

Summary of Contents for LINEAKIT Series

Page 1: ...to esterno per l ac censione del monitor e quindi ripremere lo stesso per la selezione dei posti esterni PROGRAMMAZIONE BASE senza l utilizzo di programmatori dedicati Per la programmazione della chia...

Page 2: ...Funzione dei morsetti fig 10 Morsettiera M1 da 12 16 Vca o 14 18 Vcc alimentazione locale B linea X1 ingresso chiamata dal pianerottolo Morsettiera M2 collegamento per l altoparlante YAL Funzione dei...

Page 3: ...mmazione base dei posti esterni Per ripristinare le condizioni di default vedere capitolo dedicato Ripristino condizioni di default dal posto esterno 1 Togliere il ponticello SW1 2 Chiudere il contatt...

Page 4: ...the corresponding keys following the first call button NOTE Do not exit receiver programming mode until you have associated all the desired calls To programme intercom calls see the instructions prov...

Page 5: ...r YPL accessory CN4 for YV or YVC monitor Technical features Supply voltage local 12 to 16 V AC or 14 to 18 V DC centralized 14 to 18 V DC Power supply from bus 15 20 V DC Current demand without monit...

Page 6: ...structions featu red in interface IT 300 3 Press the door lock release and auxiliary 2 but tons at the same time for at least 1 s when audio towards the entry panel is enabled the operation is confirm...

Page 7: ...cken so viel mal wie die Anzahl der gew nschten Klingelzeichen von 1 bis 6 ist In Anlagen des Systems 300 kann die Anzahl nach einer kundenspezifischen Gestaltung des Netzge r ts XA 300LR auf 51 Klin...

Page 8: ...ur nach der Verbindungsprogrammierung der An rufe von der Au enstation mit den Innensprechstellen erfolgen In Anlagen mit XA 300LR wird angeraten die an der Elementau enseite befindlichen ID SN der Sp...

Page 9: ...ivante appuyer sur la touche auxiliaire 2 lors de la pause entre le signal sonore et la m lodie R p ter l op ration jusqu ce que la m lodie souhait e soit entendue Pour enregistrer le nouveau r glage...

Page 10: ...so ciation des appels des postes ext rieurs aux postes int rieurs Dans les installations avec XA 300LR il est con seill de regruper les codes d identification ID SN des postes int rieurs appliqu s l e...

Page 11: ...nto de entrada en la programaci n colgar el auricular y esperar por lo menos 5 s Para recorrer en secuencia el tipo de funci n pul sar el bot n abrepuerta La entrada en cada funci n est identificada p...

Page 12: ...ciaci n de las llamadas desde las placas externas con los derivados internos En las instalaciones con XA 300LR se recomien da recoger los c digos de identificaci n ID SN de los derivados internos apli...

Page 13: ...as desejadas Para a programa o das chamadas intercomunican tes ver as instru es anexadas ao selector VSE 301 PROGRAMA O COM MPP 300LR OU PCS 300 poss vel programar o aparelho atrav s do MPP 300LR util...

Page 14: ...dos internos Nas instala es com XA 300LR se aconselha de recolher os c digos identificativos ID SN dos derivados internos aplicados na parte de fora do m vel e referi los nas tabelas anexas s apa relh...

Page 15: ...200 5 6 21 7 14 SW1 20 B VLS 101 A 1 2 3 A G VAS 100 1 2 1 2 HEV 301 HEVC 301 HET 301 B IN B OUT 1 2 3 4 5 19 Fig 19 Esempio di collegamento uscita ausiliaria Aux 1 o Aux 2 con l unit rel VLS 101 Alim...

Page 16: ...t siehe Gebrauchs anweisung der Au enstation ATTENTION Les appareils qui composent ce kit peu vent tre utilis s individuellement pour realiser des installations pour immeuble Pour la section des cable...

Reviews: