1 695 655 163
2010-07-17
|
Robert Bosch GmbH
Maintenance | WBE 4510 | 61
en
14.4 Calibration
i
As part of service and upkeep (every six months),
on flange replacement or in the event of measure-
ment inaccuracies, it is advisable to calibrate the
WBE 4510 in the following sequence:
1.
Flange calibration.
2.
Vernier caliper calibration.
3.
WBE 4510 calibration.
4.
Perform reference measurement.
14.4.1 Call-up of calibration menu
1.
The menu is called up from the Service page <
o
>.
2.
Enter the password: <
r
> <
r
> <
o
>.
"
The calibration menu is displayed.
i
Press <
X
> to exit from the calibration menu.
14.4.2 Flange
calibration
i
Follow the instructions shown on the monitor.
1.
Fit the flange (refer to Section 5).
i
Do not attach the wheel, do not use any clamping
tools.
2.
Start flange calibration in the calibration menu.
Press <
r
> <
r
> and <
OK
>.
3.
Press <
OK
>.
The wheel guard closes automatically.
The unbalance measurement commences auto-
matically.
"
Flange calibration completed.
"
Unbalance set to "0".
14.4.3 Electronic vernier caliper calibration
i
Follow the instructions shown on the monitor.
1.
Start calibration in the calibration menu. Press
<
r
><
r
><
r
> and <
OK
>.
2.
Set the vernier caliper (B) to the rest position and
press <
OK
>.
3.
Extend the vernier caliper (B) to 200 mm, enter this
value and press <
OK
>.
4.
Clamp a test wheel in position (ideally 13" or 14").
5.
Enter the wheel diameter and press <
OK
>.
6.
Apply the vernier caliper (B) to the rim flange and
press <
OK
>.
"
Vernier caliper calibration completed