36/60 Installation
Bosch Rexroth AG
, VT-VPCD, RE 30028-B/09.13
For the current interface, pressure transducers of type HM 20-2X/...C-K35 are used.
Pressure transducer cables must be shielded.
Cable type for the current interface: LiCYC 2 x 0.25 mm
2
up to a length of 50 m.
Fig. 21: Connection of pressure transducers with current interface
Notes on the technical data and unit dimensions of pressure transducer HM 20,
see data sheet RE 30272.
VPCD_03
z30
b22
1
4
2
3
z32
z10
b24
1
4
2
3
z30
b6
z32
z10
b8
p
B
p
A
Current interface (HM 20)
When 2 pressure transducers are used: