Safety instructions
11/60
RE 30028-B/09.13, VT-VPCD,
Bosch Rexroth AG
WARNING
High electric voltage due to incorrect connection!
Danger to life, risk of injury through electric shock.
▶
Only connect devices, electrical components and lines which feature protective
extra low voltage (PELV) to connections or terminals having voltages from 0 to
50 Volt.
▶
Only connect voltages and power circuits that feature safe isolation from
dangerous voltages. Safe electrical isolation can be achieved for example with
isolating transformers, safe optocouplers or mains-free battery operation.
High voltage!
Risk of injury.
▶
Wire or plug in the control electronics VT-VPCD only when it is disconnected
from the power supply.
Lightning!
Risk of uncontrolled machine movements.
▶
An inadequate grounding concept or missing equipotential bonding can lead to
damage to the electronics. Ensure equipotential bonding for the device.
Failures and defects in the control current circuits or the energy supply!
Risk of uncontrolled machine movements.
▶
Ensure safety in accordance with EN ISO 13849 or IEC 62061.
CAUTION
Hot surfaces!
Risk of burning. System parts can heat up during operation.
▶
Let system parts cool down before touching them or wear protective gloves.
Fault currents and short-circuits!
Reduced safety and malfunction.
▶
The environment must be free from conductive contamination (acids, lyes,
corrosive agents, salts, metal vapors, etc.) and the device must not be exposed
to them. Generally, rule out deposits according to protection class IP 65.