Company Registered in England No: 4167649 VAT Registration No: 732 5692 25 BS EN ISO 9001:2008 No: LRQ 0964389
+44 (0)1204 699 959
Hyquip Limited New Brunswick Street Horwich Bolton Lancashire BL6 7JB UK
www.hyquip.co.uk
/web/index
12/60
General notes on damage to material and the product
Bosch Rexroth AG
, VT-VPCD, RE 30028-B/09.13
3 General notes on damage to material and
the product
The warranty is valid exclusively for the configuration delivered.
t
Warranty claims will be rejected in the case of improper installation,
commissioning and operation as well as in the case of use not in accordance with
the intended purpose and/or improper handling.
NOTICE
High voltage!
Possible damage to the control electronics.
▶
Wire the control electronics only when it is disconnected from the power supply.
Overheating!
Possible damage to the control electronics.
▶
Adhere to the ambient conditions according to the data sheet.
▶
Do not use free-wheeling diodes in the solenoid cables.
▶
Ensure sufficient ventilation of air.
Overloading!
Risk of overloading and damage to supply cables in the case of insufficient
dimensioning and/or operation with several electrical devices.
▶
Provide current limitation by overload protection.
▶
Select an appropriate rating of power supply unit and cables.
Short-circuit!
Risk of overloading of and damage to the supply cable in the case of a defect of
electrical equipment.
▶
Provide current limitation by means of overload protection.
Electrostatic discharge!
Risk of damage to components of the control electronics.
▶
Provide equipotential bonding to discharge static voltage from your body.
▶
Work in a safe environment.
▶
Do not use devices that generate or have static discharge in the working
environment.
▶
Do not carry out any work on the control electronics in environments that could
generate static charges.
▶
Handle the control electronics with care. Do not touch exposed connection pins
and sensitive components of the electronics.
▶
Transport and store the control electronics carefully in the original packaging
provided for this purpose.
Wrong cables! Voltage loss, scorching of cable!
Risk of damage to the product.
▶
For solenoid cables up to 50 m long, use cable type LiYCY 1.5 mm², for position
transducer cables, cable type LiYCY 0.5 mm² shielded. For greater lengths,
please consult us.