Installation 35/60
RE 30028-B/09.13, VT-VPCD,
Bosch Rexroth AG
b32
b28
2
1
3
4
5
b12
b28
b10
z10
Fig. 19: Connection of swivel angle transducer MCP-40/4742
The transducer is connected by means of soldered connections.
Up to a length of 50 m we recommend the use of 3 x 0.5 mm² cables of type LiYCYCY
as connection cable. When double-shielded cables are used, the outer shield can be
terminated at the entrance in the control cabinet, the outer shield can be terminated
at the control electronics.
For the voltage interface, pressure transducers of type HM 20 -2X/...H-K35 are used.
Pressure transducer cables must be shielded.
Cable type for the voltage interface: LiCYC 4 x 0.25 mm
2
up to a length of 50 m.
Fig. 20: Connection of pressure transducers HM 20 with voltage interface
Pressure transducer side A
and/or side B
1
4
2
3
z30
b22
b24
z10
z32
1
4
2
3
z30
b6
b8
z10
z32
p
B
p
A
Voltage interface (HM 20)
When 2 pressure transducers are used: