Fig. 15: Connection of the solenoids to the control electronics
Use a mating connector CECc 75301-803-A002FAH3008-G according to
DIN EN 175 301-803 and ISO 4400 for connecting the solenoids.
t
Solenoid “a”, mating connector, color: gray, separate order stating material no.
R901017010
t
Solenoid “b”, mating connector, color: black, separate order stating material no.
R901017011
The transducer is connected using a 4-pin mating connector Pg7-G5W1F, which can
be ordered separately stating material no. R900023126.
Up to a length of 50 m we recommend the use of 4 x 0.25 mm² connection cables
of type LiYCYCY. When double shielded cable is used, the outer shield can be
terminated at the entry into the control cabinet, the inner shield can be terminated
at the control electronics.
The shield needs only to be connected to pin z10 of the edge connector on the
supply side.
z14
z12
z16
z18
1 3
2
4
z10
Fig. 16: Connection of the valve position transducer to the control electronics (viewed to
connection side)