No "external data" available in case of a new control.
3.
Select the tab "Control data". Select the settings for the NC archive un‐
der "Edit".
Select the NC archives to be loaded. The archives are filed in the de‐
fault project in the >Project Directory>\TAR directory
4.
Select all options to restore data
5.
Select the tab "Drive data". The drive archives can be selected under
"Edit". The drive archives are filed in the default project in the >Project
Directory>\PAR directory
6.
Check your entries and start restoration by clicking on "Finish"
7.
Restoration comprises 3 phases, and the control repeatedly restarts ac‐
cordingly
8.
This dialog shows the successful restoration of the CNC configuration
data
DOK-MTXMIC-EASY*******-CO06-EN-P
Bosch Rexroth AG
69/177
IndraMotion MTX micro Easy Setup for Standard Turning and Milling Machines
Software installation and basic projects