The data of the control is completely overwritten during the re‐
store procedure. Please check beforehand whether there is data
that is still required.
Version 10VRS and 12VRS
Proceed as follows to restore data from a USB flash drive:
1.
Insert a USB flash drive containing the data backup into the port on the
VDP80 control panel. After it has been detected by the system, an ap‐
propriate message is displayed.
2.
Switch to the <Maintain> operating area
3.
Press the <F9> (Restore) key
4.
Wait until the "Restore done" message is displayed, which may take up
to 15 minutes.
5.
Disconnect the USB flash drive.
6.
Switch the control off and on again. In exceptional cases, it may be re‐
quired to switch the control off a second time until all parameters are ac‐
tive and the control starts without error message.
The data of the control is completely overwritten during the re‐
store procedure. Please check beforehand whether there is data
that is still required.
11.1.4
Serial commissioning
The data backup and restore operations are perfectly compatible with a serial
commissioning of machines.
After the prototype machine has been commissioned, the data is stored to a
USB flash drive. This data backup is used to restore the data for all serial ma‐
chines. It is even possible to manage several data backups by copying or re‐
naming the "/Backup" directory on the USB flash drive.
Currently, IndraWorks Engineering does not allow downloading
the data backup from a USB flash drive.
Bosch Rexroth AG
DOK-MTXMIC-EASY*******-CO06-EN-P
150/177
IndraMotion MTX micro Easy Setup for Standard Turning and Milling Machines
Data backup and serial commissioning