55/57
Bosch Rexroth Canada ı 03.10.2011 ı Revision 5.4
19.
19.
19.
19.
Do engines need to be ramped up to normal RPM inst
Do engines need to be ramped up to normal RPM inst
Do engines need to be ramped up to normal RPM inst
Do engines need to be ramped up to normal RPM instead of idle RPM
ead of idle RPM
ead of idle RPM
ead of idle RPM
during nulling?
during nulling?
during nulling?
during nulling?
It is recommended to ramp up engine RPM to ensure sufficient hydraulic flow for
valves to operate. Possibly for vehicles with bigger pumps there is enough hydraulic
flow at idle RPM.
20.
20.
20.
20.
What types Temp Sensors do CS
What types Temp Sensors do CS
What types Temp Sensors do CS
What types Temp Sensors do CS----440RC cont
440RC cont
440RC cont
440RC controllers support?
rollers support?
rollers support?
rollers support?
Currently the CS-440RC controllers support two types of Infra-re temp sensors,
Sprague Roadwatch and 996D Temp sensor from Controls Products Inc.
21.
21.
21.
21.
What are the pin outs of the CS
What are the pin outs of the CS
What are the pin outs of the CS
What are the pin outs of the CS----440RC digital inputs?
440RC digital inputs?
440RC digital inputs?
440RC digital inputs?
For Solid
For Solid
For Solid
For Solid +
+
+
+ Pre
Pre
Pre
Pre----wet Operation
wet Operation
wet Operation
wet Operation
For An
For An
For An
For Anti
ti
ti
ti----Icing Operation
Icing Operation
Icing Operation
Icing Operation
1 – Material Detection
2 – Material Change
3 – Low Liquid Pressure
4 – Plow Indicator
5 – Spare
6 – P-Float Indicator
7 – Low Oil Indicator
8 – Body Up Indicator
1 – Left Boom
2 – Liquid Change
3 – Low Liquid Pressure
4 – Right Boom
5 – Centre Boom
6 – P-Float Indicator
7 – Low Oil Indicator
8 – Body Up Indicator
22.
22.
22.
22.
The Display screen is blank:
The Display screen is blank:
The Display screen is blank:
The Display screen is blank:
If the power switch light is not illuminated then:
•
Possible sensor or solenoid short circuit
•
Possible extender cable short circuit
•
Unplug peripheral sensors and solenoids until problem goes away
•
Replace defective sensor/solenoid
There is a time delay breaker in the knob console that may take a few seconds to
trip upon a fault condition. This will cause the display to blank. The breaker will
reset when the fault is corrected.
Some severe short circuits or circuit misuse can cause damage to the knob console.
If the power switch remains illuminated then:
•
Unplug peripheral cables on the back of the display (i.e. temp sensor, GPS,
digital input cable)
•
Check/replace the short interconnect between the display and the knob console
•
If problem persists, the console may require service form the factory