53/57
Bosch Rexroth Canada ı 03.10.2011 ı Revision 5.4
It uses the conveyor motor exhaust oil to operate the Pre-wet system.
12.
12.
12.
12.
Why is Trip Summary lost when CS440RC is turned off?
Why is Trip Summary lost when CS440RC is turned off?
Why is Trip Summary lost when CS440RC is turned off?
Why is Trip Summary lost when CS440RC is turned off?
Since the Trip Summary is the duplicated information as the logged data it is not
stored in battery backed memory, and it loses upon power off.
13.
13.
13.
13.
What ar
What ar
What ar
What are ways to calibrate ground speed?
e ways to calibrate ground speed?
e ways to calibrate ground speed?
e ways to calibrate ground speed?
•
Use INPUT PULSES. Check total pulses per km/mi from truck transmission
datasheet. Put it into ->PROGRAM MODE ->SENSORS & VALVES->GRND SPD
SENSOR->INPUT. It is recommended for trucks with new tires. Once tires wear
out it would affect accuracy.
•
Use Ground Speed AUTO CALIBRATION. ->PROGRAM MODE->SENSORS &
VALVES->GRND SPD SENSOR-AUTO CALIBRATION. On the SPEED screen set
the speed to the typical driving speed, drive to the speed, and Press START. It
takes a few seconds to complete. Upon completion the current driving speed
would show up on the bottom right corner of the screen.
•
Use TRIP SUMMARY. This needs to be done on a section of measured road.
Clear the TRIP SUMMARY, drive from the beginning to the end of the marked
distance, check the total pulses for the distance, calculate the total pulses for 1
km/mi, and put into GROUND SENSOR->INPUT. (The first line of the Trip
Summary toggles units between km/mi and pulses each time it is accessed.)
14.
14.
14.
14.
How to set up or null min/max outp
How to set up or null min/max outp
How to set up or null min/max outp
How to set up or null min/max outputs of a Conveyor valve?
uts of a Conveyor valve?
uts of a Conveyor valve?
uts of a Conveyor valve?
•
To set up manually, ->PROGRAM MODE->SENSORS & VALVES->CONVEYOR
SETUP->VALVE SETTINGS, ensure that correct pulses are put in, Select Min Out,
Press ENTER to go into edit mode (an cursor should show up under one digit),
Press Up/Down on the keypad to adjust valve output to a point that the
conveyor barely starts to move( rpm reading on the bottom right about to ramp
up), Press ENTER again to exit edit mode.
•
To set up automatically, ->PROGRAM MODE->SENSORS & VALVES->CONVEYOR
SETUP->VALVE SETTINGS, ensure that correct pulses are put in, Select AUTO
NULL, Press ENTER to select, and ENTER again to start. Once AUTO NULL stops
it completes.
Note: For very slow conveyors (max RPM < 100) the AUTO NULL may start twice to
calculate correct max RPM value.
15.
15.
15.
15.
How to set up or null min/max outputs of a Spinner valve?
How to set up or null min/max outputs of a Spinner valve?
How to set up or null min/max outputs of a Spinner valve?
How to set up or null min/max outputs of a Spinner valve?
•
For MANUAL operation (default) no feedback sensor is required. Select -
>PROGRAM MODE->SENSORS & VALVES->SPINNER SETUP->VALVE SETTINGS-
>Spinner, Select Min Out or Max Out, Press ENTER to go into edit mode (an