8.3.3
Areas with blocking time
Disarming of an area can be optionally influenced by means of a blocking time. An external
alarm from the area cancels the blocking time, i.e. disarming is possible.
1.
Under
Area
(area manager), select the desired
Time Model
.
Please note: Disarming is possible within a defined time interval.
2.
A
Time Model
is made up of
Day Models
and can be adapted or created in the user
manager if necessary.
3.
A blocking time can be changed by the user at the control center up to seven days in
advance if the user has the corresponding permissions.
User Manager > Permission Sets
> Operations Category > May Edit Blocking Time
8.3.4
Access Levels
The standard distinguishes between four access levels (AE):
–
AE 1 Access for everyone, no authorization/code required
–
AE 2A Access for users, user passcode required
–
AE 2B Access for users, user passcode required
–
AE 3 Access for installers via
control center
or via
RPS for MAP
–
AE 4 Access for manufacturers via
RPS for MAP
Level 2A is a subset of level 2B.
Selecting the access level
AE 1 Access for everyone, no authorization/code required
AE 2A Access for users, user passcode required
AE 2B Access for users, user passcode required
AE 3 Access for installers via
control center
1.
Open control panel enclosure.
The internal warning device is activated for 3 sec.
1
2.
Switch to installer mode (refer to Installer button, page 66).
3.
Enter installer passcode.
AE 3 Access for installers via
RPS for MAP
1.
Open control panel enclosure.
Internal warning device is activated for 3 sec.
1
or
authorize from RPS with an AE 2 user with corresponding permissions (control center:
main menu page 2 > RPS).
2.
Establish a connection between the panel and RPS.
AE 4 Access for manufacturers via
RPS for MAP
1.
Authorize the manufacturer user with an AE 3 user with corresponding permissions
(control center: main menu page 1 > maintenance page 3 > manufacturer permission).
2.
Open control panel enclosure.
The internal warning device is activated for 3 sec.
1
3.
Switch to installer mode = AE 3 (Installer button, page 66).
4.
Login with the passcode of the manufacturer at the installer control center (Manufacturer
authorization, page 59).
5.
Establish a connection between the panel and RPS.