MAP 5000
Installation | en
17
Bosch Security Systems B.V.
Installation manual
2019-09 | 25 | F.01U.168.332
2.3
Mounting the enclosure
Notice!
Ensure that there is enough free space to the left of the enclosure so that the enclosure door
and the ICP-MAP0025 hinged mounting plate have full range of motion.
- For a fully opened door, at least 460 mm (18 in) is required.
- For a door opened at 90°, at least 32 mm (1.25 in) is required
.
1.
Use the supplied drill template to mark the holes on the intended surface.
The drill template can be found in the enclosure box.
2.
If a wall tamper is required, insert the plug for the tamper switch into the back of the
enclosure (required in accordance with EN50131 grade 3) as shown in the figure below.
3.
Secure the plug to the wall using a suitable screw (not supplied).
Inserting the wall tamper plug
ICP-MAP0111
1.
Mount the enclosure to the intended surface using suitable screws and anchors (not
supplied). Use the mounting holes as shown in the figure below.
2.
Ensure that all screws are tight and that the enclosure is securely fastened to the
mounting surface.