Connecting the DE module
3.7
Installing and connecting the tamper switch
–
Install the ICP-MAP0050 control panel enclosure tamper switch in the ICP-MAP0111 panel
enclosure.
–
Install the ICP-MAP0055 expansion enclosure tamper switch in the ICP-MAP0120
expansion enclosure.
Installing the tamper switch onto the rail
4
Slide the extension piece of the tamper switch to position C as shown in the figure
below.
If a wall tamper plug was installed (refer to Mounting the enclosure, page 17), the position
of the expansion piece of the tamper switch must be chosen in a way that lifting the
enclosure off the wall by > 5 mm leads to reliable activation of the tamper switch.