62
en | Initial set-up and programming
MAP 5000
2019-09 | 25 | F.01U.168.332
Installation manual
Bosch Security Systems B.V.
Entry delay active
From start of entry delay until
–
end of entry delay
–
disarming of the area
Reportable duress alarm
Reporting of duress alarm event
Reportable hold-up alarm
Reporting of hold-up alarm event
Reportable amok alarm
Reporting of amok alarm event
Reportable external intrusion
alarm
Reporting of external intrusion alarm event, possibly also
delayed if present/absent option is used
Reportable external tamper
alarm
Reporting of external tamper alarm event, possibly also
delayed if present/absent option is used
Reportable panel summary
trouble
Reporting of panel summary trouble event, possibly also
delayed if present/absent option is used
Reportable panel summary
armed
Reporting of panel summary armed
Reportable external fire alarm
Reporting of duress alarm event, possibly also delayed if
present/absent option is used
Anti-mask intrusion trouble
Covering of a motion detector
External tamper alarm disarmed Tamper alarm from disarmed area with simultaneous
reporting via the communicator
Transmission path fault
In the event of communication failure between
communicator and receiver
Ethernet path layer1 fault
In the event of failure of connection to network connector
Wireless path layer1 fault
In the event of failure of connection to network
–
field strength insufficient
–
registration not possible
–
GPRS service not available
–
no connection to the DE module
IPC reporting failure
No acknowledgment received from the receiver within 240
sec.
S1S Transmission Path Fault
Communication failure between panel and communicator
S1S Reporting Failure
Panel has received negative acknowledgment from
communicator
Open Intrusion Interface
Trouble
Trouble in connection via Open Intrusion Interface
Silence Area x
Silence sirens and buzzer of area x
Reset Area x
Clear events of area x