MAP 5000
Appendices | en
81
Bosch Security Systems B.V.
Installation manual
2019-09 | 25 | F.01U.168.332
3.
The schedule can optionally be edited at the control center.
Schedule > Behavior > May
Be Edited At Control Center
.
Chime mode
If
Chime Mode
is activated on the control center in disarmed state, tripping of an intrusion
point with the option
Chime Mode Capable
leads to a one-off chime tone on the control
center.
4
Assign the point to the
local area
of the control center.
8.3
Requirements in accordance with SES
The basis for this requirement is the standard EN 50131 grade 3 (refer to Requirements in
accordance with EN 50131 grade 3, page 74). Deviations from this standard are already taken
into account in the fundamental behavior of the panel and / or described below.
8.3.1
Selecting the default setting
1.
Select EN50131 grade 3 as the default property values setting (refer to Standard-
compliant programming, page 58).
2.
If the panel validation in accordance with EN 50131 grade 3 fails, do
not
proceed with
programming the panel.
See also
–
Point types and point evaluation, page 59
–
Standard-compliant programming, page 58
8.3.2
Automatic arming / disarming
Arming without a warning signal is permitted if it is possible to ensure by technical or
organizational measures that there are no persons in the supervised area before arming.
–
Refer to Automatic arming / disarming, page 76.
Automatic arming at a predefined time with warning signal
1.
Start the schedule wizard and define the time of arming.
2.
As action, select
Arm Area(s) Using Exit Delay
.
3.
Program the duration of the acoustic warning signal before arming in the area:
Area
Manager > Area > Exit Delay > Normal Delay Time
.
4.
Deactivate the option
Arm Only If Area Is Ready To Arm
.
5.
Optionally program automatic bypassing of points.
Automatic arming at a predefined time without warning signal
–
Start the schedule wizard and define the time of arming.
–
As action, select
Arm Area(s) Immediately
.
–
Optionally program automatic bypassing of points.
Automatic arming after disarming without warning signal
–
Enter the duration after disarming when automatic arming is about to take place in the
area.
Area Manager > Area > Behavior > Automatic Arming after Disarming
.
–
Optionally program automatic bypassing of points.
Disarming at a predefined time
Automatic disarming is
not
permitted for security reasons.
See also
–
Automatic arming / disarming, page 76
–