58
en | Initial set-up and programming
MAP 5000
2019-09 | 25 | F.01U.168.332
Installation manual
Bosch Security Systems B.V.
Installing the programming software
1.
Insert the CD in the drive and start the installation process by double-clicking on the
setup.exe
file in the
RPS
directory.
2.
Follow the instructions of the installer.
P
RPS for MAP will start automatically after installation has been completed successfully.
Logging on for the first time
The dialog box login information is displayed when the program is started for the first time
after installation.
1.
Enter
admin
as user name and
default
as password.
2.
After successful login, the administrator password and language can be changed. To do
this, change to the tab
Administration > Operators
.
P
The password
default
is deactivated if the administrator password is changed.
4.2.1
Help for the programming software
All instructions and explanations for programming are provided online, i.e. directly on the
screen.
Help texts in the properties info bar
If you mark a parameter in the
Properties
field on the
Main Page
tab, a short explanation will
be displayed in the
Properties Info Bar
underneath.
Detailed information is available by pressing the F1 function key on your PC keyboard.
Help texts in the contents overview
The complete programming process with all operating steps is described in the contents
overview.
4
Click on the ? button.
4.2.2
Standard-compliant programming
If you want to perform standard-compliant programming, select the following settings in RPS
before you start programming.
1.
Click on the yellow RPS button and create a new panel account with the
New
button.
2.
In the
Hardware Manager
, click on the
MAP 5000 Panel
node and then in the Properties
field on the parameter
Default Property Values Set
and select the standard that you
want to program.
3.
Right-click on any parameter on the left side of the Properties window.
4.
Select
Restore all properties using <selected standard> default property values set
.
Confirm with
Yes
.
Compliance check / validation
During programming, you can check whether programming is compliant with the selected
standard at any time.
4
Click on the
Panel Validation
button.
P
Any errors found will be displayed in the
Error List
window in plain text.
4.3
Panel software
Fault-free operation of the panel can be guaranteed only if
all
system modules of the panel
and programming software comply with the manufacturer's specifications.
4.3.1
Checking the software version
After first start-up, you need to check whether the software versions of all system modules
and the programming software are compatible with each other (refer to MAP 5000 system
bundles).