1st: Choose the
sensor´s category
2nd: Narrow your
choice by
choosing a type
3rd: Select the
exact type
Opens sensor´s
datasheet
These calibration
values will be used
4. Click ‘Finish’ when done.
The ‘Create channel’ window opens.
5. Enter channel name and description.
6. Click ‘Ok’ when done.
The channel is inserted into the DDU 7 Project Tree.
Channel is linked
to ANA03
Input pin Pull-up
resistor is activated
Calculation of
physical value with
characteristic curve
Available measurements for channel:
Measurement label
Function
raw_name
mV value of sensor
raw_name_fi
Filtered mV value of sensor
name
Physical value of sensor
name_fi
Filtered physical value