CHAPTER 5. REFRIGERATION CYCLE
[1] SCHEMATIC DIAGRAM
s
1
4
C
2
Accumulator
3
Strainer
Expansion
valve
Heating
Cooling
Outdoor unit
Condenser
Evaporator
Indoor unit
Reverse valve
Comp-
ressor
Flare coupling
Flare coupling
3-way
valve
2-way
valve
Silencer
Coil
Antifreeze
pipe*
5
*
Only model CLC6101i-W 50 HE / CLC6101i 50 HE, CLC8101i-W 65 HE(T/S/R) have antifreeze pipe.
[2] STANDARD CONDITION
Indoor side
Outdoor side
Dry-bulb Temp. (°C)
Relative Humidity (%)
Dry-bulb Temp. (°C)
Relative Humidity (%)
Cooling
27
47
35
40
[3] TEMPERATURE AT EACH PART AND PRESSURE IN 3-WAY VALVE
Model
CLC6101i-W 50 HE, CLC6101i 50 HE
CLC6101i-W 65 HE, CLC6101i 65 HE
Cooling
Heating
Cooling
Heating
Mode
Max *1
Test Run *2
Max *1
Test Run *2
Max *1
Test Run *2
Max *1
Test Run *2
Ampere(A)
3.9
3.1
6.6
2.6
5.9
3.2
9.8
2.5
3-way valve pressure (MPaG)
1.0
1.1
3.1
2.1
0.9
1.1
3.4
2.1
Indoor Outlet Temperature (5) (°C)
14
15
43
32
12
16
50
31
Temperature(°C)
(1)
74
69
94
62
86
67
92
62
(2)
39
40
2
3
41
40
1
4
(3)
12
13
25
27
11
15
45
23
(4)
14
16
2
4
9
16
1
4
Summary of Contents for CLC6001i 25 E
Page 69: ...2 Climate Class 6100i 6000i 8100i 8000i 6 1 6 3 6 4 6 2 ...
Page 77: ...10 Climate Class 6100i 6000i 8100i 8000i 6 1 6 3 6 4 6 2 ...
Page 87: ...20 Climate Class 6100i 6000i 8100i 8000i 7 28 Reverse Value Ass y ...
Page 88: ...21 Climate Class 6100i 6000i 8100i 8000i Expansion Value Ass y ...