Check if the power supply voltage during
comperessor operating is within rated voltage
±10%.
Check if the air filter and heat exchanger of IDU
has been blocked by dust etc, or the ODU air
outlet has been blocked.
Check if the temperature of 2-way-valve pipe
gets cool under cooling mode and gets warm
under heating mode, during compressor
operating.
Check if the ODU fan operates normally.
Correct the cable between IDU and ODU ,
or connect air conditioner to stable
power source.
Clean air filter and heat exchanger of IDU
and ensure the air flow from air outlet
not be blocked.