6-14
Climate Class 6100i / 6000i / 8100i / 8000i
4)
Disassemble terminal holder
,
if terminal holder broken.(1 screw)
5)
Disassemble cover.
6)
Disassemble 4 screw, then disassemble control
board unit.
(Disassemble 7 screws on control board unit.)
(Disassemble control board unit.)
Notice:
2)
3)
4)
5)
Don’t plug between fixing terminal and sleep.
1. Exchange outdoor circuit board.
2) Reconnect terminals in order after exchanging the
1) Remove the fixing terminals(T5, 7~9).
(Pull it out after pressing the delocking pin.)
Sleep
Tab
One side of the
fixing terminal
isn’t buckled
Pay attention to the lock pin when pluging the city block
fasten terminal.Try not plug the terminal by hand,or clip
the lock part with radio pench.
Don’t clip it with radio pench
It’s inappropriate that the tension in the fasten terminal
is too big when wiring.
The terminal once removed can’t be used again,because
the interlocking decreases.It’s necessary that use it after
compressing it a little.
Compress it a little
control basal lamina.
Don’t pull the wire to remove the terminal.
The notes of the fixing terminals connection.
1)
Please pull and remove the terminal straight along the tab.
2.
Note
:
Before change control board unit
,
the workmen should
wear anti-eletrostatic gloves.
Summary of Contents for CLC6001i 25 E
Page 69: ...2 Climate Class 6100i 6000i 8100i 8000i 6 1 6 3 6 4 6 2 ...
Page 77: ...10 Climate Class 6100i 6000i 8100i 8000i 6 1 6 3 6 4 6 2 ...
Page 87: ...20 Climate Class 6100i 6000i 8100i 8000i 7 28 Reverse Value Ass y ...
Page 88: ...21 Climate Class 6100i 6000i 8100i 8000i Expansion Value Ass y ...