5-2
Climate Class 6100i / 6000i / 8100i / 8000i
Model
CLC8101i-W 65 HE(T/S/R), CLC8101i 65 HE
CLC6001i-W 25 E, CLC6001i 25 E
Cooling
Heating
Cooling
Heating
Mode
Max *1
Test Run *2
Max *1
Test Run *2
Max *1
Test Run *2
Max *1
Test Run *2
Ampere(A)
4.9
2.8
7.9
2.4
3.9
3.1
6.1
2.6
3-way valve pressure (MPaG)
0.9
1.1
3.1
2.0
1.0
1.1
3.0
2.2
Indoor Outlet Temperature (5) (°C)
13
16
46
30
14
15
42
31
Temperature(°C)
(1)
76
62
94
60
75
71
90
64
(2)
38
37
2
3
39
39
2
3
(3)
12
15
30
21
12
13
32
26
(4)
10
14
1
5
13
15
3
5
Model
CLC6001i-W 35 E, CLC6001i 35 E
CLC8001i-W 25 E(T/S/R), CLC8001i 25 E
Cooling
Heating
Cooling
Heating
Mode
Max *1
Test Run *2
Max *1
Test Run *2
Max *1
Test Run *2
Max *1
Test Run *2
Ampere(A)
6.1
3.2
7.8
2.6
3.1
3.8
5.7
2.5
3-way valve pressure (MPaG)
0.9
1.1
3.3
2.2
1.1
1.1
2.8
2.0
Indoor Outlet Temperature (5) (°C)
13
16
45
31
15
16
40
30
Temperature(°C)
(1)
85
70
94
64
66
64
89
61
(2)
40
39
2
3
37
37
2
3
(3)
10
14
34
26
14
15
23
21
(4)
7
16
2
5
14
15
4
5
Model
CLC8001i-W 35 E(T/S/R), CLC8001i 35 E
Cooling
Heating
Mode
Max *1
Test Run *2
Max *1
Test Run *2
Ampere(A)
4.9
2.8
7.9
2.5
3-way valve pressure (MPaG)
0.9
1.1
3.1
2.0
Indoor Outlet Temperature (5) (°C)
14
16
44
30
Temperature(°C)
(1)
77
63
98
61
(2)
38
37
2
2
(3)
12
15
25
20
(4)
12
15
1
5
*1 To enter cooling max, start the unit with remote control setting 16°C and high fan speed.
Check the data within 30min after start cooling.
*2 Refer to installation manual for how to enter test run.
Summary of Contents for CLC6001i 25 E
Page 69: ...2 Climate Class 6100i 6000i 8100i 8000i 6 1 6 3 6 4 6 2 ...
Page 77: ...10 Climate Class 6100i 6000i 8100i 8000i 6 1 6 3 6 4 6 2 ...
Page 87: ...20 Climate Class 6100i 6000i 8100i 8000i 7 28 Reverse Value Ass y ...
Page 88: ...21 Climate Class 6100i 6000i 8100i 8000i Expansion Value Ass y ...