Indoor Ventilation Kit

Therma Grow 120/220

120/220 Plus

View these instructions online at www.lbwhite.com

Tools required:

-- Electric drill with 1/8 in. drill bit

-- Electrical wire stripping / crimping tool 

-- 1/4 in. and 5/16 in. nut drivers

-- Standard screwdriver

-- Small adjustable wrench 

-- Saw

-- Level

Materials required:

-- Sealant caulk

-- Framing material (if needed)

-- Approved electrical wiring of proper gauge 

-- Electrical fittings

-- Electrical junction box 

-- Electrical tape

INSTALLATION INSTRUCTIONS

Qualifications for installation:

•  You must read and understand these instructions before beginning the installation.

•  You must have sufficient experience to install the kit and test for proper operation.

•  All wiring must be done in accordance with local codes. In absence of local codes, follow ANSI/NFPA 70,  

National Electrical Code.

General Information

Proper installation for heaters located within the greenhouse requires air exchange as follows:

An exhaust fan capable of providing the following discharge air:

-- Therma Grow™ 120/120 Plus heaters: 300 cfm. 

-- Therma Grow™ 220/220 Plus heaters: 550 cfm.

A shuttered air inlet louver of 120 sq. in. area used with an L.B.White specified air inlet duct kit with restrictor plate.

The inlet shutter and exhaust fan must be electro-mechanically operated and electrically interlocked with the heater.

Discussion

This kit consists of a properly sized motorized air inlet shutter, flexible duct, and exhaust fan. All items must be installed when 

the heater is located within the greenhouse.

Kit Contents:

DESCRIPTION

QTY.

Instruction

1

Inlet hood

1

Bag of terminals and hardware

1

Air inlet with transition duct

1

Motor, air inlet

1

Black 8 1/2 in. wire

1

Air proving switch

1

Exhaust fan

1

Duct kit (12 ft. x 6 in.)

1

Summary of Contents for Therma Grow 120

Page 1: ...g must be done in accordance with local codes In absence of local codes follow ANSI NFPA 70 National Electrical Code General Information Proper installation for heaters located within the greenhouse r...

Page 2: ...Air Inlet Locations END WALL DUCT COLLAR INSTALLED TO AIR INLET OF HEATER CLAMP CLAMP COLLAR WITH COVER INSTALLED TO AIR INLET 10 FT MAX FROM AIR INLET OF HEATER TO AIR INLET ALTERNATE INLET LOCATIONS...

Page 3: ...n the heater s discharge See Fig 3 The exhaust fan does not need to be directly in line to the heater 2 Provide a 10 1 4 in x 10 1 4 in square and level opening Suitable framing may be required for mo...

Page 4: ...OUNTED INSIDE GREENHOUSE GAS SUPPLY INLET HOOD MOTOR MOTOR ARM 10 32 X 1 1 4 MACHINE SCREW INSERT 10 32 WASHER WASHER SPACER 10 X 7 8 AIR PROVING SWITCH SCREW 1 4 X 3 8 2 NUT 10 32 WITH STAR WASHER 4...

Page 5: ...ee way terminal See Fig 7 Connect this assembly to terminal IND on the ignition control FIG 7 3 Connect the wiring from the junction box to the heater s control box as follows Use wire nuts supplied f...

Page 6: ...ontrol wiring instruc tions Ensure 115 VAC is supplied to the exhaust fan motor and air inlet shutter motor Both will operate when the heater starts a On start up the heater s fan motor will run for 5...

Page 7: ...TH SCREWS 500 25314 SHUTTER MOTOR 500 26012 BRACKET WITH MOUNTING SCREWS AND NUTS LEAD A LEAD A BUTT SPLICE WIRE FROM IGNITION CONTROL WITH TERMINAL REMOVED IND L1 HSI HSIG L2 W PSI FSI GV PSO FSG C A...

Page 8: ...REE WAY TERMINAL LEAD A BUTT SPLICE NEUTRAL NEUTRAL 115 VAC 115 VAC EXHAUST FAN CONNECTIONS AIR INLET SHUTTER MOTOR CONNECTIONS Contact your local L B White dealer for replacement parts and service Yo...