Indoor Ventilation Kit

Indoor Installation Kit • Therma Grow

5

FIG. 4

FIG. 5

Therma Grow ™ 120 Plus or 220 Plus  

Heaters

Connect the wiring from the junction box to the heater’s 

control box as follows:

a.  Black and white wires to wiring labeled TO VENTILA-

TION MOTORS. See Fig 5

 

--  Use wire nuts provided in the kit. 

b. Green ground wire to ground screw.

 

--  Use the spade terminal from the kit.  

Proceed to Section E.

Therma Grow™ 120 or 220 Heaters

1.  Disconnect the black motor wire at the ignition control 

terminal marked IND. See Fig.6.

FIG. 6

2. Connect the kit’s 8 1/2 in. black wire and the motor 

wire to the kit’s three way terminal. See Fig.7. Connect 

this assembly to terminal IND on the ignition control.

FIG. 7

3.  Connect the wiring from the junction box to the 

heater’s control box as follows. Use wire nuts supplied 

for a. and b.:

a.  Black wire to the stripped end of the black 8 1/2 in. 

wire.

b.  White wire to the white wire in the control box labeled 

TO VENTILATION MOTORS.

c. Green ground wire to the ground screw.

 

--  Use the spade terminal from the kit. Proceed to 

Section E.

E.  Wiring the Air Proving Switch at Air Inlet 

to the Heater’s Contol Box

1.  Disconnect the blue wire from terminal PSI on the igni-

tion control. Remove the terminal from this lead and 

strip back its insulation about 1/4 in. See Fig. 8.

FIG. 8

 

DRILLED PILOT

HOLES

INNER WALL

HOLE PLUG

WIRE CAPS

3 WAY TERMINAL

MOTOR WIRE

8 1/2 IN.

BLACK WIRE

#10 X 1/2

SCREW

Summary of Contents for Therma Grow 120

Page 1: ...g must be done in accordance with local codes In absence of local codes follow ANSI NFPA 70 National Electrical Code General Information Proper installation for heaters located within the greenhouse r...

Page 2: ...Air Inlet Locations END WALL DUCT COLLAR INSTALLED TO AIR INLET OF HEATER CLAMP CLAMP COLLAR WITH COVER INSTALLED TO AIR INLET 10 FT MAX FROM AIR INLET OF HEATER TO AIR INLET ALTERNATE INLET LOCATIONS...

Page 3: ...n the heater s discharge See Fig 3 The exhaust fan does not need to be directly in line to the heater 2 Provide a 10 1 4 in x 10 1 4 in square and level opening Suitable framing may be required for mo...

Page 4: ...OUNTED INSIDE GREENHOUSE GAS SUPPLY INLET HOOD MOTOR MOTOR ARM 10 32 X 1 1 4 MACHINE SCREW INSERT 10 32 WASHER WASHER SPACER 10 X 7 8 AIR PROVING SWITCH SCREW 1 4 X 3 8 2 NUT 10 32 WITH STAR WASHER 4...

Page 5: ...ee way terminal See Fig 7 Connect this assembly to terminal IND on the ignition control FIG 7 3 Connect the wiring from the junction box to the heater s control box as follows Use wire nuts supplied f...

Page 6: ...ontrol wiring instruc tions Ensure 115 VAC is supplied to the exhaust fan motor and air inlet shutter motor Both will operate when the heater starts a On start up the heater s fan motor will run for 5...

Page 7: ...TH SCREWS 500 25314 SHUTTER MOTOR 500 26012 BRACKET WITH MOUNTING SCREWS AND NUTS LEAD A LEAD A BUTT SPLICE WIRE FROM IGNITION CONTROL WITH TERMINAL REMOVED IND L1 HSI HSIG L2 W PSI FSI GV PSO FSG C A...

Page 8: ...REE WAY TERMINAL LEAD A BUTT SPLICE NEUTRAL NEUTRAL 115 VAC 115 VAC EXHAUST FAN CONNECTIONS AIR INLET SHUTTER MOTOR CONNECTIONS Contact your local L B White dealer for replacement parts and service Yo...