background image

HOTSPRING™ 

tankless

water heater 5kw

Scan to
download

HSTK5

Scan to
download

 

Summary of Contents for HOTSPRING HSTK5

Page 1: ...HOTSPRING tankless water heater 5kw Scan to download HSTK5 Scan to download...

Page 2: ...e electric instantaneous water heater without first shutting off all power to the unit directly from the circuit breaker box Installation of this appliance is restricted to indoor locations only by li...

Page 3: ...y Instructions Before you install How to install Water connections Electrical diagram CONNECTING CABLES AND POWER CHORDS Inside view of appliance Troubleshooting warranty CERTIFICATIONS index 1 4 5 6...

Page 4: ...flows through the appliance Powerful heating elements are activated by a flow switch as water is drawn from a hot water faucet connected to the appliance Due to the absence of stand by loss this appli...

Page 5: ...2 dimensions here s a little info about the appliance 198 mm 79 mm 160 mm Hot Water Outlet Cold Water Inlet 98 mm...

Page 6: ...r sink Easy operation the heater provides hot water with constant temperature Micro computer control adopting patented heating technology Water is completely separated from electricity by multi layers...

Page 7: ...t breaker Wire IP Rating Max Pressure Inlet Size Weight Dimension h x w x d Colour 5 kw 20 A 3 x 2 5 4 sqmm IP25 6 bar G1 2 1 96 kg 198 160 98 mm White TECHNICAL SPECIFICATIONS here s a little info ab...

Page 8: ...ting temperature will be up 1 C only in the working condition the press key is available to adjust the temperature The default setting temperature is 55 C Press continuously for 3 seconds the setting...

Page 9: ...the appliance This appliance MUST be permanently connected to the fixed circuit breaker and its reccommended to be installed vertically excluding the models which are equipped with plug DO NOT instal...

Page 10: ...ure earthing and wire are compliant with local standards The appliance must be earthed according to local standards Review voltage to ensure significant voltage fluctuations do not exist Review the TD...

Page 11: ...r in the holes Fix the appliance on the wall as illustrated below Fix the appliance on the wall with fixed nail Then fix the appliance with nail in another hole to make sure the whole appliance is ins...

Page 12: ...the outlet connection red arrow points to to the hot water outlet pipe The appliance should be connected directly to the main water supply Flush the pipe with water to remove any debris or loose parti...

Page 13: ...HERE S AN ELECTRICAL DIAGRAM OF THE APPLIANCE Model HSTK5 AC220V 240V Temperature Sensor Flowmeter R R R 3 2 1 Thermal Cut out E Leakage sensor Temperature Controllor N L Remark R Resistance T Triac...

Page 14: ...inal blocks and the circuit breaker please make sure that the metal wire ends and the terminal blocks touch completely Then tighten the screws to make sure that the full current supply can pass throug...

Page 15: ...HOW THE APPLIANCE LOOKS FROM THE INSIDE Model HSTK5 12 Sensor PCB board...

Page 16: ...needs to be shut off It does not require regular maintenance However to ensure consistent water flow it is recommended to follow the below mentioned maintenance practices Periodically remove scale an...

Page 17: ...t B Change LED 3 Functional keys not working A No water out from shower B Water pressure too low C Key or PCB damaged A Open valve to get water B Open valve to get pressure C Change key or PCB 4 Water...

Page 18: ...DS is above 100ppm Inspection report of the Zanskar s authorised technician will be treated as final and binding under the warranty for determining the defects repairs alterations required or carried...

Page 19: ...16 Certifications this appliance is assgned with international certifications...