5. Internal battery grounding (Applicable types)
Remove the appearance cover plate. Use the nut of M6 to connect the battery grounding wire with cylin
-
der head cover to make the ground connection of internal battery.
6. Electrical devices
Disconnect all electrical devices from the generating set and switch off the AC circuit breaker before start
the engine.
The generating set may be hard to start with electrical devices connected.
The power of connected electrical devices cannot limit the generating set Max power, specific power see
parameter sheet for reference.
7. Generating set grounding
The generating set must be property connected to an appropriate ground. It helps prevent electrical shock if a ground fault condition exists in the generating
set or in connected electrical devices, especially when the unit is equipped with a wheel kit.
Proper grounding also helps dissipate static electricity, which often builds up in ungrounded devices.
DANGER: Electrical Shock
Failure to properly ground the generating set can result in electric shock.
A ground terminal on the frame of the generator has been provided on the generator end.
For remote grounding, connect a length of heavy gauge (4mm²) copper wire between the generator ground terminal and a copper rod driven into the
ground.
Local electrical codes may also require proper grounding of the unit. We strongly recommend that you consult with a qualified electrician for grounding
requirements in your area.
B. Starting the generating set
1. Perform operating checklist
and remove all loads.
2. Turn the ventilation knob to "ON'' position when engine is running to make sure the fuel flowing.
3. Turn the two-in-one switch to the "RUN" position.
4. Turn the energy saving switch to the "ON" position.
Note: Please set the energy-saving switch to "OFF" position when it needs large starting current.
5. (Suitable for hand recoil starting)
Pull out the choke lever to close the choke valve.
CAUTION:
Choke position for starting may vary depending upon temperature and other factors. If re-start
-
ing a warm engine, there's no need to pull out the choke lever.
Summary of Contents for 034469
Page 1: ...Art Nr WWW BORMANNTOOLS COM en el v2 1 034469 BGB2000...
Page 17: ...WWW BORMANNTOOLS COM 18 EL 1 5...
Page 18: ...WWW BORMANNTOOLS COM 19 EL AC 1 2 3 RUN...
Page 19: ...WWW BORMANNTOOLS COM 20 EL ON OFF OFF OFF ON OFF OFF RUN ON OFF ON Reset...
Page 20: ...WWW BORMANNTOOLS COM 21 EL inverter ON OFF 1 60cm 5 000 1 500 3 5 1 000 300 5 000 1 500...
Page 21: ...WWW BORMANNTOOLS COM 22 EL 3 4 4 5 000 1 500 2...
Page 22: ...WWW BORMANNTOOLS COM 23 EL 5 M6 6 AC 7 4 mm2 B 1 2 ON...
Page 23: ...WWW BORMANNTOOLS COM 24 EL 4 ON OFF 5 6 15 3 3 RUN...
Page 24: ...WWW BORMANNTOOLS COM 25 EL ON START 0 3s 10 30 Start 7 ON 1 2 3 4 OFF 5 6 7...
Page 26: ...WWW BORMANNTOOLS COM 27 EL 3 ON 4 5 OFF E 4 1 2 3 4 PAH PAH 1...
Page 28: ...WWW BORMANNTOOLS COM 29 EL A B A 300 B...
Page 29: ...WWW BORMANNTOOLS COM 30 EL 1 2 3 4 5 0 6mm 0 8mm 6 7 15 20Nm 8 1 2 3 4 5 6...
Page 30: ...WWW BORMANNTOOLS COM 31 EL OFF RUN RUN ON 2 20 2 1 2 3 4 5 6 15ml 7...
Page 31: ...DISPOSE OF PACKAGING RESPONSIBLY DO NOT DISPOSE OF ELECTRICAL GOODS IN HOUSEHOLD WASTE...