46
Operating Instructions AEC
11/17
7.4
Size 6
The frequency inverter is mounted in a vertical position on the assembly panel by means of the standard
fittings. The following illustration shows the standard fitting.
Standard installation
Assembly is done by screwing the two fixing brackets to the heat sink of the device and the assembly panel.
The devices are provided with fixing brackets, which are fitted using four thread-cutting screws. The
dimensions of the device and the installation dimensions are those of the standard device without optional
components and are given in millimeters.
Dimensions [mm]
Assembly dimensions [mm]
AEC 401
a
b
c
a1
a1
b1
c1
-33/-35/-37/-39
400
275
260
425 … 445
470
20
160
Befestigungswinkel oben
(Befestigung mit Schrauben
)
M5x20
Befestigungswinkel unten
(Befestigung mit Schrauben
)
M5x20
a
a1
a2
x
x 100 mm
b
b1
x
c
c1