Key
Meaning
CANopen
F23
nn
Heartbeat error, nn = triggering node.
CM module identification
F24
00
Unknown CM module. Verify compatibility of firmware and CM module
EM module identification
F25
00
Unknown EM module. Verify compatibility of firmware and EM module
Industrial Ethernet
F27
nn
Industrial Ethernet error. Please note the instructions on the Ethernet module used.
User error VPLC
F30
3n
Internal PLC function error caused by the user. Please refer to VPLC user manual.
Optional components
F0A
10
Data transmission from control unit KP 500 to the frequency inverter not possible. At least one
file must be stored in the control unit.
F0B
13
The communication module was fitted to slot B without disconnection of the mains voltage,
switch mains voltage off.
Internal monitoring
F0C
40
This error is triggered after 6 warm starts in less than 3 minutes because there will probably be
an error in the programming in the PLC or the function table. In addition the function table will
be stopped (P.1399 = 0 in RAM only).
11.1.2
Output signals in the case of error messages
Errors are signaled via digital signals.
162 -
Error Signal
1)
A monitoring function reports an error displayed via Parameter
Current Error
259.
3 -
2)
1)
For linking to frequency inverter functions
2)
For output via a digital output
In addition to fault messages mentioned, there are further fault messages. However these messages are
only used for internal purposes and are not listed here. If you receive fault messages which are not listed
here, please contact the BONFILGLIOLI customer service.
Please save the parameter file on your PC before.
11.2
Error environment
The parameters of the error environment help troubleshooting both in the settings of the frequency inverter
and also in the complete application. The error environment documents the operational behavior of the
frequency inverter at the time of the last four faults.
Error environment
No.
Description
Function
330
DC-Link Voltage
Direct voltage in DC-link.
331
Output voltage
Calculated output voltage (motor voltage) of the frequency
inverter.
335
Phase Current Ia
Measured current in motor phase U.
336
Phase Current Ib
Measured current in motor phase V.
337
Phase Current Ic
Measured current in motor phase W.