Faults
5.2
Faults – Compressor
Page 42
BOGE Operating instructions for C 16 N...C 30 N, C 16 F N...C 30 F N series screw compressors
Compressor system
does not start up
No electric power to compressor
Check electrical connection
Fuses are defective
Check the mains and control fuses, replace if necessary
Machine has not vented perfectly
Check venting valve and replace, if necessary
Voltage fluctuations in the elec-
trical mains power
Ensure constant voltage in accordance with IEC 38
Compressor oil is very viscous due
to low ambient temperature
Heat compressor room
Oil in suction filter
Minimum pressure non-return
valve is leaking
Check the minimum pressure check valve and replace, if necessary
Suction controller is leaking
Check the suction controller and replace, if necessary
Switch-off performed by emer-
gency-off switch/button
Cut-out normally via
O
-key
Excessive oil
consumption
Drain line is blocked
Dismantle and clean drain line
Defective oil separator element
Check oil separator and replace, if necessary
Excessive oil filling
Drain off oil
Safety valve blows
Operating pressure target value
maladjusted
Set operating pressure to maximum permissible pressure of the
screw compressor
Defective safety valve
Replace safety valve
System pressure does
not decrease when
switching off
Venting valve does not open
Check the venting valve and replace, if necessary
Check valve is leaking
Examine check valve and replace, if necessary
Fault
Possible cause
Rectification