BOGE Operating instructions for C 16 N...C 30 N, C 16 F N...C 30 F N series screw compressors
Page 35
Installation
3.5
Commissioning
Checking compressed
air outlet for tightness
–
Close mains disconnecting device.
–
To conduct the inspection switch on the compressor and check the com-
pressed air outlet for tightness.
–
Switch off compressor.
Record the test results in the commissioning certificate.
Opening the stop valves
Open ball valve on the compressor delivery.
Checking for leaks
Undertake the following to prevent leaks:
–
Check screw connection of the lines and retighten, if necessary.
–
Check to ensure that the oil filter and oil separator are hand tight seated.
WARNING: Risk of injury!
Work on the compressed air system may only be carried out by experienced
and authorized qualified personnel!
Always wear protective clothing and goggles!
Immediately after having switched on the machine the connection of the
compressed air outlet must be checked for tightness!
Make sure to observe an appropriate safety distance during the inspection!
WARNING: Risk of injury!
Actuate emergency-stop switch/button, open mains disconnecting device
and secure by means of lock out tag out.
–
If necessary, have leakages repaired by skilled qualified pesonnel.
WARNING: Risk of injury!
In case of leakages in the oil circuit there is a certain danger to slip and fall
because of oil spills!
Have all connections of the oil circuit checked for leakages by authorized
qualified personnel!
During the inspection slip-resistant safety shoes and protective clothing are
obligatory!