15
OPTI 780
USA
· AIR VENT GRILLS must be centered NOT LESS THAN 28 INCHES ABOVE THE
TOP OPENING OF THE FIREPLACE AND NOT LESS THAN 15 INCHES BELOW
THE CEILING.
· An AIR INLET OF MINIMUM 65 SQUARE INCHES (example: 2’’ x 32.5’’) under the
appliance is MANDATORY to allow a correct cooling of appliance.
7.5.
Natural convection (no fan installed)
UL tests require
at least 1 air duct
to be installed and insulated
if a combustible mantle is
placed.
However, Bodart & Gonay advises to install 2 air ducts (one on each side) if no fan is installed.
This will cool down the appliance more effi ciently and will give more hot air circulation .
7.6. Forced
convection
(fan kit option) Reference: 37B78047
Electrical connection
: 115 V~ 60 Hz 0,72 A 85 W
THIS APPLIANCE WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED
IN ACCORDANCE WITH LOCAL CODES, WITH THE NATIONAL ELECTRICAL
CODE, ANSI/NFPA 70-1990, OR THE CANADIAN ELECTRICAL CODE, CSA
C2.2.1.
To install the fans, we advise you to take off the frame and the door.
The fan installs through the inside. Take off the 2 fi re grates (#16 parts list page 24) and their
stainless steel blocking parts (#17) in front of them, the bricks behind and on the sides (#12,
#13, #14) and the grates support (#25).
Unscrew the 6 screws from the ash-pan’s box.
Take off the ash-pan (#26), ash removal arm (#27) and then the ventilation caps (#28) through
the
ash-pan
door.
Connection to the electrical circuit is:
· green / yellow ............ ground
·
blue
............................
common
·
brown
.........................
line
INSTALLATION INSTRUCTIONS