9
OPTI 780
Trouble shooting
Cures
THE FIRE IS NOT BRISK ENOUGH
THE THERMOSTAT DOES NOT CLOSE ANYMORE:
- A foreign body prevents the closing of the fl ap
- Mechanical blocking
THE THERMOSTAT REMAINS CLOSED:
1 When COLD, the fl ap only rises from mean dial
positions
2 When COLD, the fl ap does not rise
THE FIRE CANNOT BE CONTROLLED:
- The DOOR of the ash box is open or unsealed
- The DOOR of the appliance is not sealed
- Check the moisture of the fuel;
- Check the thermostat;
- Empty the ash box;
- Clear the holes of the distributor.
- Remove the foreign body
- Replace the thermostat
- Calibrate the adjustment
- Replace the thermostat (thermostat bulb destroyed by
overheating)
- Check the correct closing of the ash box door;
- Check the seal, replace if necessary;
- Adjust again the door seal;
- Adjust again the position of the closing roller.
In case of a chimney fi re, immediately close the door, the ash box door and the thermostat .
5. GUARANTEE
5.1.
Duration and limitation
· 6 years guarantee on: the general structure;
· 2 years guarantee on: the inner removable parts;
· 1 year guarantee on: grates, thermostat, fan and variable speed control switch;
· no guarantee on: window, seals, bricks
5.2.
Reservation
Bodart & Gonay reserve the right to modify their equipment, catalogues and manuals
independently, at any time and without prior notice.
The validity of the guarantee is cancelled in case the mandatory recommendations of this
manual are not fulfi lled.
The interventions under the guarantee are only made through the dealer on presentation of
the
purchase
invoice.
Parts will be delivered only against the faulty parts.