OPTI 780

SPARE PARTS AND OPTIONS OPTIFIRE 780 USA/CN

SPARE PARTS

Ref

Code

Description

01

07BP0103

COLD HANDLE IF96+PRISMA

02

27B78016

WELDED DOOR OPTI 780 FLAT

02

27B78017

WELDED DOOR OPTI 780 ROUND

03

07RV1039

CERAMIC 656X487X4 OPTI 780

03

07RV1041

CERAMIC 900 DEV .638 H.490 EP.4 Opti 780

04

27B78015

STAINLESS STEEL  DOOR SEAL OPTI 780 FLAT

04

27B78018

GLASS HOLDER OPTI 780 BOWED

04

37B78021

ASSEMBLED DOOR SEAL OPTI 780 BOWED

05

27660002

DOOR LATCH IF 96

05

27B78022

DOOR LATCH BOWED OPTI 780

06

27660000

LATCH CATCH IF96

07

37B78014

CHICANE SUP

08

37B78015

CHICANE INF

09

07CB300

REFRACTORY BR.240X120X30 VT20

10

07CB315

REFRACTORY BRICK 300X150X30

11

07CB344

REFRACTORY BRICK 300X90X30

12

07CB313

REFRACTORY BR.240X60X30 CHAMFE

13

07CB336

REFRACT BRICK CHAMF 90X60X30

14

07CB350

CHAMFERED BRICK 180X165X30

16

07FFIFG

PAIR OF GRATES IF-GAUMAIS

17

37B78013

FRONT GRATE STOP

18

37B78012

END CAP BRICK

19

37B78010

AIR DISTRIBUTOR

20

07CB326

BRICK 150X60X30 CHAMFERED

21

07CB327

BRICK 150X60X30 CHAMFERED

22

37B78029

LOG RETAINER

23

37660016

LOG RETAINER HOLDER

24

37B78016

SPOILER OPTI 780 FLAT

24

37B78026

SPOILER OPTI 780 BOWED

25

37B78006

GRATES HOLDER OPTI 780

26

37B78008

ASHPAN

27

37B78007

ASH REMOVAL ARM

28

27B78014

VENTILATION CAPS OPTI 780

29

07PBE001

ASHPAN DOOR SPRING D950207

30

37B78040

ASHPAN DOOR OPTI USA

31

37B78044

THERMOSTAT AND PROTECTION OPTI 780 USA

33

07PBB049

FRAME SPRING

34

27B78027

DOOR FRAME 3 FLAT OPTI 780 - 760 DF

34

27B78029

DOOR FRAME 3 SIDED BOWED OPTI 780

35

37B78046

HEARTH STRIP OPTI 780 USA

36

37116226

PROBE MOUNT

37

37B77016

STABILIZER SOVEREIGN

38

37117400

HOT AIR PIPE DIA 125

39

07VM0200

PIPE ADAPTOR DIAM 200

40

37B78042

ANCHOR PLATE FOR DIA 200 PIPE OPTI 780 USA

41

37B78038

TOP SCREEN OPTI 780 USA

42

37B78003

PAIR OF FEET 780

OPTIONS

Ref

Code

Description

43

37680048

THERMOCONTACT KIT INFIRE RC93

44

27B78025

3-SIDED FRAME FOR FLAT OPTI 780

45

37B78047

fan kit opti usa 780 450 m3

46

37B78043

HOT AIR OUTLET GRID AND BOX OPTI 780 USA

INSTALLATION INSTRUCTIONS

Summary of Contents for OPTI 780

Page 1: ...1 CAN USA OPTIFIRE 780 USA CN Tested Listed By Portland Oregon USA USER S MANUAL MAINTENANCE MANUAL INSTALLATION INSTRUCTIONS V3 23 11 2004 Imported by Pound Ridge NY...

Page 2: ...conditions and in the most optimal manner and furthermore to increase its operating life WE STRONGLY ADVISE YOU TO READ IT CAREFULLY And of course to store it in a place where you are sure to nd it ag...

Page 3: ...itation 9 5 2 Reservation 9 5 3 Exclusion 10 5 4 Taking effect 10 INSTALLATION INSTRUCTIONS 6 Safety 11 7 Installation 12 7 1 Description of the re place system 12 7 2 Chimney 12 7 3 Minimum clearance...

Page 4: ...AY FROM THE FRONT OF THE FIREPLACE OPENING DO NOT USE PRODUCTS THAT ARE NOT SPECIFIED FOR USE WITH THIS FIRE PLACE DO NOT ELEVATE FIRE OR USE GRATE BUILD WOOD FIRE DIRECTLY ON HEARTH OPERATE ONLY WITH...

Page 5: ...tion air is not controlled and the re races OVERHEATING OF THE APPLIANCE 4 de ashing arm To use it pull it towards the front It is used to adapt the grate to the type of fuel to be burnt left position...

Page 6: ...lated shelter Except when starting a re NEVER OPERATE your FIRELACE with the GRATE in the OPEN POSITION Closed position Model Maximum load for low rate burning only Recommended load for 1 hour at max...

Page 7: ...with expelled moisture to form creosote The creosote vapors condense in the relatively cool chimney ue of a slow burning re As a result creosote residue accumulates on the ue lining When ignited this...

Page 8: ...r a chimney sweeping note here the ideal position see page on adjustment of the baf es Upper baf e open open closed Lower baf e open closed Place the grate in the closed position After cleaning the ch...

Page 9: ...thoroughly the surfaces then apply a HIGH TEMPERATURES RESISTANT GREASE 4 OPERATIONAL TROUBLE SHOOTING Trouble shooting Cures THE WINDOW GETS DIRTY TOO QUICKLY VENTILATION FAN Does not function VENTI...

Page 10: ...the seal replace if necessary Adjust again the door seal Adjust again the position of the closing roller In case of a chimney re immediately close the door the ash box door and the thermostat 5 GUARAN...

Page 11: ...r excessive draught incorrect use non compatible fuels destructive and or damp fuels treated wood consumption exceeding the use limits a lack of maintenance the use of electrical or electronic compone...

Page 12: ...e while working on it This will prevent any possible electrical shock or burns Any COMBUSTION consumes AIR From the gap at an entry door threshold to the direct outside air intake everyone must choose...

Page 13: ...SL324 Chimney Section 24 inch long SL336 Chimney Section 36 inch long SL348 Chimney Section 48 inch long SL3 Chimney Stabilizer SL315 Chimney Offset Return 15 SL330 Chimney Offset Return 30 FS338 Fir...

Page 14: ...ST HAVE A TWO INCHES CLEARANCE BETWEEN THE CHIMNEY AND ANY COMBUSTIBLE MATERIALS DO NOT FILL THIS SPACE WITH INSULATION OR ANY MATERIAL YOU MUST CONFORM WITH ALL RECOMMENDATIONS FROM HEATILATOR FOR US...

Page 15: ...OMBUSTIBLE MANTLE is installed ONE FRONT AIR DUCT MINIMUM must be connected with or without a fan Hot air ducts must be Aluminum 5 ex pipe wrapped with rockwool ceramic blanket or any 250 C resistant...

Page 16: ...ced convection fan kit option Reference 37B78047 Electrical connection 115 V 60 Hz 0 72 A 85 W THIS APPLIANCE WHEN INSTALLED MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES WITH THE NATIO...

Page 17: ...an wires need to pass through the dedicated hole on the left side of ash box Then you can place the switch support on the appliance and screw it Connect with the fan Place fan in the insert be careful...

Page 18: ...page 24 with the front ash pan box This ventilation cap must be removed and placed back when a fan is installed How to install a thermocontact optional Screw the thermocontact on the back side from th...

Page 19: ...l as release notch for the assembly and dismantling of the baf es The lower baf e may be turned around and thus open the passage for the smoke in the front for instance if the equipment back drafts to...

Page 20: ...19 OPTI 780 USA INSTALLATION INSTRUCTIONS The most closed position Prohibited Position Average position Most open position Lower baffle turned around...

Page 21: ...he height of the square support 3 Lift one side and try to lower the other side of the baf e by passing the square support through the notch 4 Remove the baf e by tilting it so that it passes through...

Page 22: ...gap between the appliance and the hearth extension Place the unit in the desired location Determine the height telescopic feet BEWARE Respect the minimal 2 inches intake for convection air You must in...

Page 23: ...vide a passage of the electrical feeding wire of the motor when making the installation Fix chimney connector 40 parts list page 24 to the appliance with the four screws Place the internal ue spigot 3...

Page 24: ...material on a mini mum 13 height and 1 higher than mantel bottom Air inlet for convection minimum 65 sq inches can have other shapes and locations Air discharge grid center line at 28 minimum from ap...

Page 25: ...19 37B78010 AIR DISTRIBUTOR 20 07CB326 BRICK 150X60X30 CHAMFERED 21 07CB327 BRICK 150X60X30 CHAMFERED 22 37B78029 LOG RETAINER 23 37660016 LOG RETAINER HOLDER 24 37B78016 SPOILER OPTI 780 FLAT 24 37B...

Page 26: ...25 OPTI 780 USA INSTALLATION INSTRUCTIONS...

Page 27: ...ZOO M ZOOM 6 x A B 2 x C I N O UT B D 9 3 8 7 2 4 5 6 B I N I N 1 0 FRO NT BACK IF NO HOLE 3 6in 2 6 in E 1 M4 x 10mm M3 x 0 62 in 16mm 3 5 mm 0 14 in 0 128 x 1in n 5 5 M3 x M4 x 0 39 in 3 6in 1 6in...

Page 28: ......

Reviews: