21
OPTI 780
33"
21"
38.5"
to5
1
"
USA
7.10. Installation of appliance
·
Only if the fi replace rest on a combustible surface,
a hearth extension of minimum
16’’ must be installed in front of the fi replace. It need to be extended 8’’ beyond each
side of the opening
. It is to protect the combustible fl oor from both radiant and sparks.
Place the metal hearth strip, supplied with the appliance, approximately 2 inches under the
front edge of the fi replace. It is to protect the gap between the appliance and the hearth
extension.
· Place the unit in the desired location.
· Determine the height (telescopic feet). BEWARE! Respect the minimal 2 inches intake
for convection air.
· You must insert the feet (1-2) and screw (3) the feet. Then you must pin the feet (4).
Therefore: bore a 5,25 mm diameter with the delivered bit and place the
auto tapping
screws.
(depending on feet height)
(minimum 45’
’ with a fan)
minimum without fan 3.75’’
minimum with fan installed 8’’
leg levellers
INSTALLATION INSTRUCTIONS
In the conception of rough opening, do not forget to provide the MINIMAL OPENING for
the passage of the CONVECTION AIR - inlet of minimum 65 square inches).
Summary of Contents for OPTI 780
Page 26: ...25 OPTI 780 USA INSTALLATION INSTRUCTIONS...