17
6. MAINTENANCE/STORAGE & WINTERIZATION
STORING PUMP FOR WINTERIZATION
WARNING
To avoid a dangerous or fatal electrical shock, turn OFF power to motor before
draining pump. Failure to disconnect power may result in serious personal injury
or death.
• Drain water level below all inlets to the pool.
• Remove drain plugs from bottom of strainer body, and remove strainer cover
from strainer housing.
• Disconnect pump from mounting pad, wiring system, and plumbing system.
• Once the pump is empty of water, re-install the strainer cover and drain plugs.
Store pump in a dry area.
7. TECHNICAL DATA FOR FX PRO VS II
FOR ABOVE-GROUND & IN-GROUND POOL PUMPS
DATA FOR MODEL #’s NE9881 & NE9882:
BW No.
Input
Power
WEF
Voltage
Hertz
HHP
Max Flow
Rate
Amps
Wire Size
NE9881
1 HP
9.266
115V
60Hz
0.526
2880 GPH with
1-1/2” Hose
6.4A
12AWG
4863 GPH with
2” Pipe
NE9882
1 HP
10.34
230V
60Hz
0.533
4876 GPH
3.3A
12AWG