1. SAFETY INSTRUCTIONS (CONTINUED)
Hazardous Pressure.
Pool water circulation systems operate under hazardous pressure during
start-up, normal operation, and after pump shut-off. Stand clear of circulation
system equipment during pump start-up. Failure to follow safety and operation
instructions could result in violent separation of the pump housing and cover
due to pressure in the system, which could cause property damage, severe
personal injury, or death. Before servicing the pool water circulation system,
all system and pump controls must be in the off position. The filter manual air
relief valve must be in the open position if it is part of the filtration system.
Before starting system pump, all system valves must be set in a position to
allow system water to return back to the pool. Do not change filter control valve
position while system pump is running. Before starting system pump, fully open
filter manual air relief valve. Do not close filter manual air relief valve until a
steady stream of water (not air or air and water) is discharged. All suction and
discharge valves
MUST
be
OPEN
when starting the circulation system.
Failure to do so could result in severe personal injury and/or property damage.
WARNING
Separation Hazard.
Failure to follow safety and operation instructions could result in violent
separation of pump components. Strainer cover must be properly secured to
pump housing with strainer cover lock ring. Before servicing the pool and spa
circulation system, all system and pump controls must be in the off position and
the filter manual air relief valve must be in the open position. Do not operate
pool circulation system if a system component is not assembled properly,
damaged, or missing. Do not operate pool circulation system unless filter air
relief valve body is in closed position. All suction and discharge valves
MUST
be
OPEN
when starting the circulation system.
Failure to do so could result in severe personal injury and/or property damage.
WARNING
WARNING
NEVER
operate or test the circulation system at more than
40 PSI.