background image

4

1. SAFETY INSTRUCTIONS (CONTINUED)

WARNING

Some pump

 components have a finite life. All components should be inspected 

frequently and replaced if found to be worn, damaged, broken, cracked, or 
missing.

Risk of Electric Shock

.

Hazardous voltage. Can shock, burn, or cause death. To reduce the risk of 
electric shock, do NOT use an extension cord to connect unit to electric supply. 
Provide a properly located outlet. It is required that licensed electricians do all 
electrical wiring. All electrical wiring MUST be in conformance with applicable 
local and national codes and regulations. Before working on pump or motor, 
disconnect motor wiring.

WARNING

WARNING

Do NOT bury cord. Place the cord on the ground so it can avoid abuse from 
lawn mowers, hedge trimmers and other equipment.

Connect only to a grounding type receptacle protected by a Ground Fault 
Circuit Interrupter (GFCI). Contact a licensed electrician if you cannot verify that 
the receptacle is protected by a GFCI.

Failure to bond pump to pool structure will increase risk for electrocution 
and could result in injury or death. To reduce the risk of electric shock, see 
installation instructions and consult a professional electrician on how to bond 
pump.
Also, contact a licensed electrician for information on local electrical codes 
for bonding requirements. Use a solid copper conductor, size 8 or larger. 
Run a continuous wire from external bonding lug to reinforcing rod or mesh. 
Connect a No. 8 AWG (8.4 mm2) solid copper bonding wire to the pressure wire 
connector provided on the motor housing and to all metal parts of swimming 
pool, spa, or hot tub, and to all electrical equipment, metal piping (except gas 
piping), and conduit within 5 ft. (1.5m) of inside walls of swimming pool, spa, or 
hot tub. 

IMPORTANT

 - Reference NEC codes for all wiring standards including, but not 

limited to, grounding, bonding, and other general wiring procedures. 

NOTE

 - The National Electrical Code (NEC) permits use of a cord with a 

maximum 3 ft. (1 m) length. If your pump is equipped with a cord complying 
with the NEC, the preceeding four (4) hazards apply.

WARNING

WARNING

WARNING

WARNING

Failure to install according to defined instructions may result in severe personal 

injury or death.

Use of unauthorized replacement parts voids warranty.

Summary of Contents for FLOWXTREME PRO VS II

Page 1: ...NE9882 FLOWXTREME PRO VS II VARIABLE SPEED POOL PUMPS FOR ABOVE IN GROUND POOLS Questions problems missing parts Before returning to your retailer call our Consumer Hotline at 1 800 759 0977 Monday F...

Page 2: ...S 7 ELECTRICAL WIRING INSTRUCTIONS 9 START UP OPERATIONS 11 PROGRAMMING VARIABLE TIME SPEED OPERATIONS 13 MAINTENANCE STORAGE WINTERIZATION 16 TECHNICAL DATA FOR FX PRO VS II ABOVE GROUND IN GROUND PU...

Page 3: ...lls read this manual carefully and completely WARNING CAUTION To reduce risk of injury do not permit children to use or climb on this product Closely supervise children at all times Components such as...

Page 4: ...lectrocution and could result in injury or death To reduce the risk of electric shock see installation instructions and consult a professional electrician on how to bond pump Also contact a licensed e...

Page 5: ...lled a minimum of three feet 3 0 91 meter apart as measured from near point to near point Dual suction fittings shall be placed in such locations and distances to avoid dual blockage by a user Dual su...

Page 6: ...alve Do not close filter manual air relief valve until a steady stream of water not air or air and water is discharged All suction and discharge valves MUST be OPEN when starting the circulation syste...

Page 7: ...urther reduce vibration and stress on pipe or hose joints The base MUST be solid level rigid and vibration free Pump installation should Allow pump inlet height to be as close to water level as possib...

Page 8: ...tting by hand and then use a tool to engage fitting an additional 1 turns Use care when using Teflon tape as friction is reduced considerably Do NOT over tighten fitting or you may cause damage If lea...

Page 9: ...may overheat causing overload tripping and reduced component life If voltage is less than 90 or more than 110 of rated voltage when motor is running at full load consult Power Company Grounding and Bo...

Page 10: ...ump has pre attached power cords with 3 prong grounded plugs If local electrical codes call for power cords with twist lock plugs please check with your local professional pool store or online for ava...

Page 11: ...ully opening filter manual air relief valve until a steady stream of water is discharged 4 Allow no more than 40 psi 276 kPa at a water temperature no higher than 100 F 38 C 5 Run pressure test for no...

Page 12: ...water source is higher than the pump as is normal with above ground installation pump will prime itself when suction and outlet valves are opened If the water source is lower than the pump as is norma...

Page 13: ...nual mode has four default speeds LOW MEDIUM HIGH FULL 1 2 The default speeds cannot be changed However you can adjust to a temporary pump speed within a default setting with the UP or DOWN buttons 1...

Page 14: ...nt all parameters Start Time End Time and Running Speed are displayed The parameter being programmed flashes Press the SET button to start programming your T1 operating time and speed segment Use the...

Page 15: ...own button once the setting under this segment will be deleted Review the button functions below for additional programming information 3 0 BUTTON DESCRIPTION AND FUNCTIONS Diagram 4 3 1 RUN STOP BUTT...

Page 16: ...self lubricating motor bearings and shaft seals No lubrication is necessary Keep motor clean Do NOT use water to hose off motor Occasionally shaft seals must be replaced due to wear or damage Replace...

Page 17: ...y and remove strainer cover from strainer housing Disconnect pump from mounting pad wiring system and plumbing system Once the pump is empty of water re install the strainer cover and drain plugs Stor...

Page 18: ...ling 2 2 PM21022 NEP20233 NE9881 NE9882 3 Intake and Discharge O Ring 2 PM2103 NEP20234 NE9881 NE9882 4 Motor Shell 1 PM2104 NEP20235 NE9881 NE9882 5 Drain Plug O Ring 2 PM2105 NEP20236 NE9881 NE9882...

Page 19: ...NE9882 3 Intake and Discharge O Ring 2 PM2103 NEP20234 NE9881 NE9882 4 Motor Shell 1 PM2104 NEP20235 NE9881 NE9882 5 Drain Plug O Ring 2 PM2105 NEP20236 NE9881 NE9882 6 Drain Valve 2 PM2106 NEP20237...

Page 20: ...the phase loss is resolved 5 Communication Loss Protection When a communication failure occurs between the display PCB and the main PCB inside the pump the error code CP is displayed and the pump stop...

Page 21: ...ad protector will allow the motor to automatically restart once the motor has cooled It will continue to shut off until the problem is corrected Be sure to correct cause of overheating Motor Hums But...

Page 22: ...l dealer can confirm this with a vacuum gauge You may be able to check by removing the skimmer basket and holding your hand over the bottom port with skimmer full and pump running If no suction is fel...

Page 23: ...ount the pump on a level surface and secure the pump to the equipment pad 3 Foreign matter in pump housing Loose stones debris hitting impeller will cause noise Solution With the pump turned off or di...

Page 24: ...nses for removal installation or replacement of the product or components are not covered under this warranty The manufacturer reserves the right to make substitutions to warranty claims if parts are...

Reviews: