34 EQAM-420B
User Manual
System Watchdog:
when Enabled, automatically reboots the unit, if the operating system stops working or the status
LED turns status green or off. When Disabled, manual reboot is required in case of above events. Possible options are
Enabled and Disabled.
System Reboot:
allows the user to remotely reboot the unit.
Remote Control Port IP Address:
is the static IP address that is assigned to the Control 10/100 Port. It allows the user to
access the unit via the web interface. The factory default IP address is 172.16.70.1.
Remote Control Port Subnet Mask:
is the Subnet Mask assigned to the Control Port of the unit. It allows the user to
determine which subnet the Control Port IP address belongs to. The factory default Subnet Mask is 255.255.255.0.
Remote Control Port Default Gateway:
is the gateway address assigned to the Control Port. It allows the user to access
the unit from another network via the web interface. The factory default Default Gateway is 172.16.70.254.
Local Control 1 IP Address:
is the static IP address that is assigned to the Local Control 10/100 Port. It allows the user to
access the unit via the web interface.
Local Control 1 Subnet Mask:
is the Subnet Mask assigned to the Local Control Port of the unit. It allows the user to
determine which subnet the Local Control Port IP address belongs to.
Local Control 1 Default Gateway
: is the gateway address assigned to the Local Control Port. It allows the user to access
the unit from another network via the web interface.
1 GIGE IP Address (GIGE1): is the static IP address assigned to the Gigabit Ethernet (GigE) port.
1 GIGE IP Address (GIGE2): is the static IP address assigned to the Gigabit Ethernet (GigE) port.
Event Log Destination:
is the IP address of the remote server, to which Syslog sends the activities recorded by EQAM-
420B for monitoring and troubleshooting purposes. The factory default value is 172.16.70.2.
Log Destination Port #
: is the Event Log Destination port to which a duplicate of the error messages created by the unit can
be forwarded for monitoring and troubleshooting purposes. The factory default value, which cannot be modified, is 514.
Time Server IP
: is the IP address for the Time Server from where the unit can obtain its clock reference (See Section 6.8
for details). The factory default value is 172.16.70.2.
IGMP Version Support
: is selectable support for IGMPv2 or IGMPv3
Syslog Errors:
enable/disables the EQAM-420B to forward error messages (in red font) to an SNMP syslog. The factory
default value is disabled.
Make sure the IP address assigned to 10/100 IP Address
and
1 GigE IP Address (see & above)
are in different network address ranges or sub-networks.
Example: If the 10/100 IP Address = 172.16.70.100,
10/100 Subnet Mask = 255.255.255.0, and
1 GigE IP Address = 172.16.70.110,
then you will not be able to communicate with the unit as the
10/100 Remote Control
and
Data (1
GigE) ports (see & of Section 2.2 for details) belong to the
same subnet.
Therefore, assign 1 GigE IP Address = 192.168.253.1 or 172.16.100.98 to ensure that the
10/100 Remote Control
and
Data (1 GigE) ports belong to different address ranges (when using
192.168.253.1) or subnets (when using 172.16.100.98).