11
EQAM-420B
User Manual
Section 3 – Installation & Power-up
3.1 Unpacking
You will find the following items in the box:
• EQAM-420B (QTY=1)
• Power Cord with IEC C13 line socket and 3-pin Type B NEMA 5 plug (QTY=1)
• Blonder Tongue part# 741021800 containing Ethernet cross cable (QTY=1; see Section 4 for details)
3.2 Installation
The EQAM-420B is designed to be installed in a standard 19-inch (483 mm) rack (EIA 310-D, IEC 60297, and DIN 41494
SC48D). To install the unit, secure the unit’s front panel to the rack by inserting four (4) machine screws, with cup washers,
through the four (4) mounting holes in the front panel.
3.3 Power-up
To power up the unit, connect the line cord to a 115/230 VAC – 60/50 Hz outlet. Please note that the power inlet plug is
also equipped with a fuse-holder and fuse (SLO-BLO, 3.0 Amp, 250V).
Do not block the unit's air intake or air discharge openings.
For safe and reliable operation, the ground pin of the power cord plug must be grounded properly.
EQAM-420B and the GigE Switch are considered as elements of an integrated solution.
When a power cycle or re-boot is deemed necessary for one element, it may be
necessary to power cycle one or all of the other elements as well.