14.
LED indicators brightness level
The keypad must be activated, see NMT Start CANopen Node message.
Identifier
400h + current CAN ID
Default 415h
Byte 0
XXh
Intensity 00h-3Fh
à
min-100%
Byte 1, 7
00h
Not used
Examples:
Direction
Identifier Format Message
LED
To Keypad
415
Std
1F 00 00 00 00 00 00 00 Brightness = 50%
To Keypad
415
Std
3F 00 00 00 00 00 00 00 Brightness = 100%
15.
Backlight brightness level
The keypad must be activated, see NMT Start CANopen Node message.
Identifier
500h + current CAN ID
Default 515h
Byte 0
XXh
Intensity 00h-3Fh
à
0-100%
Byte 1, 7
00h
Not used
Examples:
Direction
Identifier
Format Message
LED
To Keypad
515
Std
00 00 00 00 00 00
00 00
Turn off the backlight
To Keypad
515
Std
10 00 00 00 00 00
00 00
Backlight brightness =
25%
SDO Messages:
A SDO (Service Data Object) is providing direct access to object entries of a CANopen
device's object dictionary.
16.
Object 2000h: Digital input module, keys states
This module contains all the Switch State information.
A one indicates the switch is pressed, a zero indicates the switch is released.
•
PKP 1500LI
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
00h
CAN Object 2000h
Byte 2
20h
Byte 3
01h
Sub index
Byte 4,7
00h
Not used