ACT5 DIGITAL KEYPAD 

30 SECOND PROGRAMMING GUIDE

 

 

(for typical system) 

1.

Enter Programming Mode.  

Press X button followed by the programming 

code (9999)  

       The LED will flash Amber 

2.    

Change User 1 code. 

       Press 0, then 1 followed by the new user 1 code 

       (four d igits)                                

 

3.

Change Programming Code.  

Press 0, then 

ü

 followed by the new program-

ming code (four digits). 

4.    

Set Desired Relay Active Time

.  

Press 2, then 0. Allow the buzzer to sound for 

the desired period. Press 

ü

 to stop –

 this period 

is now programmed into the relay timer. 

5.    

Exit Programming Mode. 

Press the X button. The  LED will be Red.

 

 

 

The keypad is now ready for normal use. 

 

  

Note: The keypad may be returned to its factory 

d efault condition at any time by entering the pr

o-

gramming mode and pressing the

 ü

       

 

three times. 

 

 

Restoring Factory Defaults

 

(From Programming Mode)  

üüü

 (Factory Defaults Restored & Keypad exits programming mode)  

If the progra mming code has been forgotten.

 

 1.        

Remove the power from the unit.  

 2.        

Remove link LK1. 

 3.        

Apply power to unit. 

 4.        

Replace link LK1.

 

 5.        

Remove power again.  

 6.        

Restore power and proceed with programming. 

Note: 

The keypad will not operate correctly without LK1 in place.

 

Incorrect Code Lockout  

        

When three invalid codes have been entered in a row. The keypad will 

enter lockout mode for 20 seconds.  During this time,  the red indicator 

will flash and all user coded will be inactive.  

        

      

ACT5 Digital Keypad Programming 

 

To enter programming mode: 

Press the X button followed by the engineering code (initially all 9999) The

 

LED will flash Amber while in programming mode . If  X is pressed at any           

time or no key is pressed within 30 seconds, programming mode is exited.

 

 

Changing Codes: 

(from programming mode)  

Enter    

0                        

(Change codes)  

    

         0

-9, 

ü

                

(user number 0-9

ü

 = programming code)  

    

         0000

-9999

          

(4 digit code – 0000 deletes user)

 

    

         Default user codes : Programming = 9999, User 1 =1234,

 

    

         All others inactive.

 

Setting the Relay active time: 

(from programming mode)  

Enter 2  

                        (Set Relay active Time)

 

         0

                          

(Relay Timer) {Buzzer sounds indicating timing…

 

  

         

                         

                       

wait required period}  

         

ü

                         

(Stop timing)  {Buzzer stops —

 timer set}  

IMPORTANT 

As with any access control system, always ensure that there is 
an alternate means of escape in the event of the unit failing to 
operate  due to power loss or in the event of fire. 

  

           

              Unit 8, IDA Business Park,        

     Whitestown, Dublin Ireland.        

           Tel: 353-1-4622585 Fax: 353-1-4622587,  
Copyright 

 2003 Access Control Technology Ltd.  

                                                                         (18-00001-27)   

         INSTALLATION NOTES  

 

Always remember to factory default the controller before 
you start programming. 

 

Always remember to place the supplied Varistor  

         across the terminals of the door strike coil to protect                     
         the relay contacts. 

 

Never  use the onboard relay to switch AC mains voltage. 
An external relay isolated electrically from the ACT5 
should be used for this purpose.          

        

 

Don’t  forget to change the programming code to some-
thing known only to yourself.  

 

 