background image

GEM

-

TOUCH

 Keypad Installation Instructions

 

1

 

 

push the wire back into the drilled wall center hole until the rear 

case is flat against the wall surface.  Insert screws through the 

rear case mounting holes and secure.

 

 

 

If replacing an existing Gemini keypad:

  Use the Wall Plate 

Adapter instructions on page 2.  Use the existing 4

-

wire or 14

-

pin harness.  

 

 

 

If  installing  onto  a  double

-

gang  box:

    Insert  mounting 

screws through the two vertical elongated holes on the left side 

of the case and into the box.  If the box is visible when viewed 

from  the  front,  adjust  the  keypad  vertically  and  tighten  the 

screws.    Then,  using  hardware  suitable  for  the  mounting 

surface, add one or two screws at the right side of the keypad 

case directly into the wall.  

 

 

 

Note: 

Do not over tighten the mounting screws!

  An uneven 

surface may cause the keypad case to distort.  

 

 

 

Assemble the keypad by placing the top edge of the keypad 

front case over the two hooks at the top of the rear case.  Push 

the bottom of the keypad until it snaps together. 

 

 

OPTION JUMPER

 

 

Cut wire loop 

W1 

to enable 

S1 

tamper switch.  

 

DESCRIPTION

 

 

The  GEMINI  GEM

-

TOUCH  keypad  is  compatible  with  the 

NAPCO  Gemini  Series  GEM

-

P816,  GEM

-

P1632,  GEM

-

P1664, GEM

-

P3200, GEM

-

X255 and GEM

-

P9600.  

Note:

  For 

systems  with  multiple  keypads,  all  keypads  must  be  all 

"classic"  (GEM

-

RP  prefix)  or  all  "K  Series"  (GEM

-

K  prefix).  

Keypad types cannot be mixed.  

 

 

SPECIFICATIONS

 

 

See product label.

 

 

Boot Current:

  249mA peak

 

 

Nominal Operating Current:

  148mA peak

 

 

Current During USB Update:

  198mA peak

 

 

PGM:

   Maximum 5mA, +12V nominal.  

 

 

Environmental: 

 32°F to 122°F (0°C to 50°C)

 

 

INSTALLING THE KEYPAD

 

 

Requires  power  from  the  control  panel  bus  (observe  current 

limitations)  or  an  un

-

switched  separate  power  supply  (panel 

ground must be common with power supply ground).  Select a 

location  that  allows  the  power  wires  to  be  hidden  within  the 

mounting surface.  Requires a battery backup power source to 

avoid  troubles  if  power  is  interrupted.    Mount  a  keypad  near 

each  exit/entry  door  (indoors  locations  only).    In  Residential 

Fire Installations, Home Run all keypads.  

Note:   

The keypad 

fire and panic buttons are not a substitute for a listed manual 

initiating device (such as a pull box).  

 

 

 

Do not power the keypad during the mounting process.  De-

tach the rear case by  pressing the two  push

-

tabs at  the bot-

tom, then unhook and detach.  

 

 

 

For  new  installations:

  Use the rear case as a template to 

mark  the mounting  holes  (always  use  a  level  to  ensure  hori-

zontal  mounting).    Mark  the  center  hole  for  the  power  wire, 

then use a 1/2" drill bit to drill the center hole.  Snake the pow-

er wire inside the wall and out through the drilled center hole.  

If mounting to hollow drywall or similar surface, we recommend 

using wall anchors or similar hardware appropriate for the in-

stallation.  Firmly connect the power wire connectors and then 

GEM

-

TOUCH Keypad 

 

Installation Instructions

 

© NAPCO 2021

 

WI2479CLF  12/21

 

333 Bayview Avenue, Amityville, New York 11701

 

For Sales and Repairs, (800) 645

-

9445

 

For Technical Service, (800) 645

-

9440 or visit us at

 

Tech.NapcoSecurity.com

 

(Note:  Technical Service is for security professionals only)

 

Publicly traded on NASDAQ      Symbol: NSSC

 

REMOTE BUS

 

All Zone End of Line 

Resistors are 2.2K

 

BROWN 

PGM 

12V 

(To control panel)

 

 

Tap/Hold-down 

Tap/Hold-down 

SYSTEM READY 1

 

09/14/28  8:15PM

 

(GEM

-

TOUCH Keypad)

 

WIRING FOR GEM

-

TOUCH

 

Disconnect power source before wiring to terminals

 

COLOR

 

FUNCTION

 

PANEL TERMINAL

 

RED 

12V PWR 

BLACK 

PWR GND 

10 

GREEN 

KEYPAD RX 

11 

YELLOW 

KEYPAD TX 

12 

BROWN 

PGM OUTPUT 

Max 5mA, +12V Nominal 

-- 

GRAY 

ZONE COMMON 

-- 

ORANGE  

ZONE 1 

-- 

BLUE  

ZONE 2 

-- 

GRAY 

ZONE COMMON 

-- 

VIOLET 

ZONE 3 

-- 

WHITE  

ZONE 4 

-- 

GRAY 

ZONE COMMON 

-- 

Important Note: 